Related Experiment Video
Updated: Jun 4, 2026

Imaging and Quantification of the Hepatic Vasculature of Mice Using Ultrafast Doppler Ultrasound
Published on: July 19, 2024
Assessment of global liver blood flow with quantitative dynamic contrast-enhanced ultrasound
Thomas P Gauthier1, Harpreet S Wasan, Aun Muhammad
1Imperial College London, London, England; Philips Healthcare, Bothell, Washington, USA. t.gauthier08@csc.mrc.ac.uk
Objectives:
This study assessed the potential of quantitative analysis of contrast bolus kinetics to reflect global liver blood flow.
Methods:
A dynamic contrast-enhanced ultrasound flow phantom was developed. A peristaltic pump established constant volume flow ranging between 16.5 and 49.5 mL/min (2-mm tube) and 85.5 and 256.5 mL/min (5-mm tube). After bolus injection of 2 doses of a contrast agent, a region of interest was drawn over the cross section of the tube used for a particular acquisition; the rise time, peak intensity, and wash-in slope were derived from time-intensity curves. Twenty healthy volunteers and 25 patients with biopsy-proven colorectal liver metastases were scanned with dynamic contrast-enhanced ultrasound. The rise time, peak intensity, and wash-in slope were derived from hepatic artery and portal vein time-intensity curves. Hepatic artery/portal vein ratios of the parameters were also calculated.
Results:
In the in vitro experiment, the rise time decreased while the peak intensity and wash-in slope increased with increasing volume flow for both tube diameters and contrast bolus volumes. In the clinical study, the rise time was lowered in the hepatic artery but elevated in the portal vein, and the peak intensity and wash-in slope were elevated in the hepatic artery but lowered in the portal vein in patients with colorectal liver metastases compared with healthy volunteers, although not in a statistically significant manner. This finding was consistent with an increase in hepatic artery blood flow, a decrease in portal vein blood flow, or both in patients with colorectal liver metastases compared with healthy volunteers. Only the 3 hepatic artery/portal vein ratios of the parameters achieved statistical significance in differentiating healthy volunteers from patients with colorectal liver metastases (P < .05).
Conclusions:
Surrogate measurements of liver blood flow may be derived from quantitative analysis of dynamic contrast-enhanced ultrasound studies. They may have potential for quick and easy assessment of altered hepatic hemodynamics.
More Related Videos
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test