Related Experiment Video
Updated: Jun 4, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Risk factors associated with early- versus late-onset implantable cardioverter-defibrillator infections
Muhammad R Sohail1, Salwa Hussain, Katherine Y Le
1Division of Infectious Diseases, Department of Medicine, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905, USA. sohail.muhammad@mayo.edu
Aims:
The infection rates of implantable cardioverter-defibrillators systems (ICDs) are higher than that of permanent pacemaker. Risk factors associated with ICD infection have not been characterized and are the subject of the current investigation.
Methods:
All patients who had an ICD implanted at Mayo Clinic Rochester between 1991 and 2008 were retrospectively reviewed. Each case of ICD infection was matched with two non-infected controls. Cases of ICD infection were further stratified by early- (≤ 6 months) versus late-onset (>6 months) infection. Multivariable analysis was performed to identify significant risk factors for ICD infection.
Results:
Sixty-eight patients with ICD infection and 136 matched controls met the inclusion criteria. Thirty-five cases presented with early-onset infection and 33 had late-onset device infection. Staphylococcal species were the most common pathogens in both groups of patients. Patients with early-onset infection were more likely to present with generator pocket infection (p = 0.02). Patients with multiple comorbid conditions (high Charlson index) tended to have longer hospital stay during implantation admission (p = 0.009). In a multivariable logistic regression model, the presence of epicardial leads (odds ratio (OR) = 9.7, p = 0.03) and postoperative complications at the generator pocket (OR = 27.2, p < 0.001) were significant risk factors for early-onset ICD infection, whereas longer duration of hospitalization at the time of implantation (2 days versus 1 day: OR = 33.1, p < 0.001; ≥ 3 days versus 1 day: OR = 49.0, p < 0.001) and chronic obstructive pulmonary disease (OR = 9.8, p = 0.02) were associated with late-onset infections.
Conclusions:
Our study findings suggest that risk factors associated with early- and late-onset ICD infection are different. While circumstances that may increase the chances of pocket contamination in the perioperative period are more likely to be associated with early-onset ICD infection, overall poor health of the host may increase the likelihood of late-onset ICD infection. These factors should be considered when developing strategies to minimize risk of device infection.
Related Concept Videos
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin create...
Endocarditis I: Introduction
Endocarditis II: Clinical Features of Infective Endocarditis
Endocarditis III: Medical Management
Endocarditis IV: Nursing Management
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies. Common...