Related Experiment Video
Updated: Jun 4, 2026

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Assessment of left ventricular regional wall motion and ejection fraction with low-radiation dose helical dual-source
Ryo Nakazato1, Balaji K Tamarappoo, Thomas W Smith
1Department of Imaging (Division of Nuclear Medicine), Cedars-Sinai Heart Institute, Cedars-Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA 90048, USA.
Background:
Electrocardiographic (ECG)-based tube current modulation during cardiac CT reduces radiation exposure but significantly increases noise in parts of the cardiac cycle where tube current is minimized.
Objective:
We evaluated the effect of maximal ECG-based tube current reduction on left ventricular (LV) regional wall motion assessment and ejection fraction (EF) by comparing low-radiation helical dual-source CT (DSCT) to 2-dimensional transthoracic echocardiography (2D-TTE).
Methods:
We studied 83 consecutive patients (15 with prior myocardial infarction) who underwent helically acquired DSCT coronary angiography with maximal ECG-based tube current modulation (low-radiation helical DSCT) and 2D-TTE within a 6-month period (median, 1 day), without any change in clinical status between the studies. In all patients, full tube current was applied only at 70% of the R-R interval, with minimal tube current (4% of maximum) in all other parts of the cardiac cycle. Reduced tube voltage (100 kVp) was combined with the maximal dose modulation in 34 patients. DSCT datasets were evaluated by a blinded, experienced cardiologist. Regional wall motion was assessed with the standard 17-segment model, with each segment scored as normal, hypokinetic, akinetic, and dyskinetic.
Results:
Mean effective radiation dose for the low-radiation helical DSCT was 5.2 ± 1.7 mSv. Regional wall motion was evaluable in all segments on low-radiation helical DSCT. There was excellent agreement of wall motion scoring by low-radiation helical DSCT and 2D-TTE in 1382 of 1411 segments (98%; Cohen's κ value 0.83; 95% confidence interval, 0.76-0.89; P < 0.0001). Mean LVEF was 67.6% ± 10.3% on low-radiation helical DSCT and 61.8% ± 10.3% on 2D-TTE (P < 0.0001).
Conclusion:
Low-radiation dose helical coronary CT angiography with maximal ECG-based tube current modulation is comparable to 2D-TTE for regional wall motion and EF assessment.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

