Related Experiment Video
Updated: Oct 26, 2026

Personalized 3D-printed Headgear for Multi-electrode Transcranial Electrical Stimulation
Published on: September 9, 2025
Design and Test Novel EEG Electrode Attachments for Type 4 Afro-textured Hairstyles
Abstract:
Black participants remain underrepresented in electroencephalography (EEG) research, partly because current EEG devices work poorly with dense, coily Type 4 Afro-textured hair. Research-grade EEG typically wires electrodes on a cap, and therefore the electrodes often fail to reach the scalp through dense, Afro-textured hair. Protocols that ask Black participants to unbraid or restyle protective hairstyles add burdens that discourage enrollment in research studies. To address this, we designed and tested 3D-printed attachments that fit onto an EEG electrode and anchored it directly in the hair, using the hairstyle itself as the mounting structure. We fabricated three design configurations for natural Afro-textured hair, cornrows/braids, and twists/microlocs. Seventeen healthy adults with Type 4a-4c hair used electrode attachments that matched their hairstyle. During a single visit, EEG was recorded with 16 conventional cap electrodes defined by the international 10-20 system and with 16 electrodes using novel electrode attachments anchored directly to their hair. Participants completed resting and walking trials with each system. Electrode-to-scalp distance and gel volume were measured during setup. Electrode disconnection, impedance, signal quality (i.e. peak alpha power and aperiodic (1/f) component), and comfort level were measured throughout the data collection. Compared with the conventional cap, the novel attachments reduced electrode-to-scalp distance, gel use, and impedance. Twenty percent of the conventional cap electrodes failed to connect to the scalp compared with 0.1% of novel electrodes. Impedance rose across trials for the conventional cap, whereas the novel attachments showed a smaller increase and maintained lower impedance throughout. Signal quality was significantly better using the novel attachments, while comfort level did not differ between systems. In conclusion, hair-anchored electrode attachment may present a feasible alternative to conventional cap-based EEG for people with Type 4 hair, yielding more usable channels and better signal quality, and supporting more inclusive EEG acquisition.
More Related Videos
11:00Reliable Acquisition of Electroencephalography Data during Simultaneous Electroencephalography and Functional MRI
Published on: March 19, 2021
09:29Preparation and Implantation of Electrodes for Electrically Kindling VGAT-Cre Mice to Generate a Model for Temporal Lobe Epilepsy
Published on: August 17, 2021