Related Experiment Video
Updated: Jun 3, 2026

A Test Bed to Examine Helmet Fit and Retention and Biomechanical Measures of Head and Neck Injury in Simulated Impact
Published on: September 21, 2017
Door velocity and occupant distance affect lateral thoracic injury mitigation with side airbag
Jason J Hallman1, Narayan Yoganandan, Frank A Pintar
1Department of Biomedical Engineering, Marquette University, Milwaukee, WI, USA. jhallman@mcw.edu
Abstract:
The relationship between thoracic injury risk and parameters of door velocity and occupant distance was delineated in blunt lateral impact with side airbag deployment. A sled impact model was exercised with the validated MADYMO fiftieth percentile facet occupant model and a generalized finite element torso side airbag. Impact velocity was incremented from 4.0 to 9.0m/s; occupant-airbag distance (at time of airbag activation) was incremented from 2.0 to 24.0 cm; simulations without airbag were also examined. Using compression, deflection rate, and the Viscous Criterion, airbag performance was characterized with respect to occupant injury risk at three points of interest: occupant distance of most protection, distance of greatest injury risk, and the newly defined critical distance. The occupant distance which demonstrated the most airbag protection, i.e., lowest injury risk, increased with increasing impact velocity. Greatest injury risk resulted when the occupant was nearest the airbag regardless of impact velocity. The critical distance was defined as the farthest distance at which airbag deployment exacerbated injury risk. This critical distance only varied considering chest compression, between 3 and 10 cm from the airbag, but did not vary when the Viscous Criterion was evaluated. At impact velocities less than or equal to 6m/s, the most protective occupant location was within 2 cm of the critical distance at which the airbag became harmful. Therefore, injury mitigation with torso airbag may be more difficult to achieve at lower ΔV.
Related Concept Videos
Impulse
Additionally, it can be shown that the total...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Collisions in Multiple Dimensions: Problem Solving
A small car of mass 1,200 kg traveling east at 60 km/h collides at an intersection with a truck of mass 3,000 kg traveling due north at 40 km/h. The two vehicles are locked together. What is the...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Cardiopulmonary Resuscitation II: ACLS Airway Management
Elastic Collisions: Case Study

