Related Experiment Video
Updated: Jun 3, 2026

Fast and Accurate Exhaled Breath Ammonia Measurement
Published on: June 11, 2014
Factors contributing to the variability observed in duplicate forensic breath alcohol measurement
1Breath Alcohol Test Program, Washington State Patrol, 811 East Roanoke, Seattle, WA 98102, USA. Rod.Gullberg@wsp.wa.gov
Abstract:
Several factors contribute to the variability observed among repeated measurements of breath alcohol concentration. Identifying these factors and the magnitude of their contribution is the focus of this study. Large breath alcohol data sets consisting of duplicate test results from drivers arrested for driving while intoxicated were obtained from four jurisdictions: Sweden, Alabama, New Jersey and Washington State. The absolute difference between duplicate results were fitted to a multivariate linear regression model which included the following predictor variables: mean breath alcohol concentration, absolute exhalation time difference between repeated measurements, absolute exhalation volume difference, gender and age. In all data sets considered here, the breath alcohol concentration was the most statistically and practically significant predictor of absolute difference between the duplicate results. The next two most important predictors to enter models for all jurisdictions were exhalation volume difference and exhalation time difference. The maximum multivariate R² for any jurisdiction, however, was only 0.24, suggesting that other factors not considered here may be of importance. Two predictors over which the subject would have some influence included exhalation time and volume. When these were set at values expected to have maximum impact, the effect on duplicate test differences was very small, 0.008 g/210 L or less in all jurisdictions, indicating that subject manipulation of exhalation time and volume would have at most a very small systematic effect on estimated breath alcohol concentration. This study presents multivariate models useful for identifying the impact of five variables that may influence breath test variability.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Uncertainty in Measurement: Accuracy and Precision
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
Eyewitness Memory
One such error is memory distortion, which occurs because human memory does not function like a...
Uncertainty in Measurement: Reading Instruments
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...

