Related Experiment Video
Updated: Jun 3, 2026

16:16
Genetically-encoded Molecular Probes to Study G Protein-coupled Receptors
Published on: September 13, 2013
An OFF-ON fluorescent probe for Zn2+ based on a GFP-inspired imidazolone derivative attached to a 1,10-phenanthroline
1Shanghai Key Laboratory of Functional Materials Chemistry & Department of Chemistry, East China University of Science and Technology, 130 Meilong Road, Shanghai 200237, PR China.
Abstract:
A green fluorescent protein chromophore inspired chemosenor for Zn(2+) was designed and synthesized. A Zn(2+) specific fluorescence enhancement was observed due to restricted rotation between the 1,10-phenanthroline and imidazolone moieties.
Related Concept Videos
Labeling DNA Probes
DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Reporter Genes
Reporter genes are a type of protein-coding gene that are often tagged to a gene of interest. Once inside a target cell, reporter genes usually produce visually identifiable characteristics like fluorescence and luminescence when expressed along with the gene of interest. Thus, reporter genes “report” the presence or absence of genes of interest in an organism, determine the gene expression pattern, or track the physical location of a DNA segment or protein in the cell.
Commonly used reporter...
Commonly used reporter...
Photoluminescence: Applications
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...