Related Experiment Video
Updated: Jun 3, 2026

Non-contact, Label-free Monitoring of Cells and Extracellular Matrix using Raman Spectroscopy
Published on: May 29, 2012
Raman microspectroscopic and dynamic vapor sorption characterization of hydration in collagen and dermal tissue
Qihong Zhang1, K L Andrew Chan, Guojin Zhang
1Department of Chemistry, Rutgers University, Newark, NJ 07102, USA.
Abstract:
Water is an integral part of collagen's triple helical and higher order structure. Studies of model triple helical peptides have revealed the presence of repetitive intrachain, interchain, and intermolecular water bridges (Bella et al., Structure 1995, 15, 893-906). In addition, an extended cylinder of hydration is thought to be responsible for collagen fiber assembly. Confocal Raman spectroscopy and dynamic vapor sorption (DVS) measurements of human Type I collagen and pigskin dermis were performed to probe relative humidity (RH)-dependent differences in the nature and level of collagen hydration. Raman spectra were also acquired as a function of time for both Type I collagen and pigskin dermis samples upon exchange of a 100% RH H(2) O to deuterium oxide (D(2) O) environment. Alterations in Amide I and III modes were consistent with anticipated changes in hydrogen bonding strength as RH increased and upon H → D exchange. Of note is the identification of a Raman spectral marker (band at 938 cm(-1) ) which appears to be sensitive to alterations in collagen-bound water. Analysis of DVS isotherms provided a quantitative measure of adsorbed and absorbed water vapor consistent with the Raman results. The development of a Raman spectral marker of collagen hydration in intact tissue is relevant to diverse fields of study ranging from the evaluation of therapeutics for wound healing to hydration of aging skin.
More Related Videos
08:49Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy
Published on: December 1, 2023
09:32Resolving Water, Proteins, and Lipids from In Vivo Confocal Raman Spectra of Stratum Corneum through a Chemometric Approach
Published on: September 26, 2019
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Reticular Dermis
Reticular Layer
Underlying the papillary layer is the much thicker reticular layer, composed of dense, irregular connective...