Related Experiment Video
Updated: Jun 3, 2026

Implantation of hiPSC-derived Cardiac-muscle Patches after Myocardial Injury in a Guinea Pig Model
Published on: March 18, 2019
Surgical repair of a complete endocardial cushion defect in a dog
Shigeki Yamano1, Masami Uechi, Katsuyuki Tanaka
1Veterinary Cardiovascular Medicine and Surgery Unit, Department of Veterinary Medicine, College of Bioresource Sciences, Nihon University, Kanagawa, Japan.
Objective:
To describe surgical repair of a complete endocardial cushion defect (ECD) in a dog.
Study Design:
Clinical report.
Animal:
A 5-month-old, 9.2 kg male Shetland sheepdog.
Methods:
Echocardiographic examination revealed an ostium primum atrial septal defect (ASD), an inlet ventricular septal defect (VSD), mitral regurgitation (MR) and tricuspid regurgitation (TR), and a complete ECD was diagnosed. Surgical correction was performed using cardiopulmonary bypass (CPB) via right atriotomy. A polytetrafluoroethylene (PTFE) patch was secured along the margin of the inlet VSD using simple continuous suture, then the cleft in the septal mitral leaflet was sutured. Similarly, the cleft in the septal tricuspid leaflets was sutured. To complete inlet VSD closure, the VSD patch was secured to these sutured leaflets by simple continuous suture. Another PTFE patch was used to close the ostium primum ASD.
Result:
After surgery, MR, TR, and interventricular shunting were decreased. The dog was alive 6 years and 5 months after the surgery with no evidence of an interventricular shunt, TR, or other clinical signs.
Conclusions:
Complete ECD in a dog was corrected using a 2-patch technique under CPB.