Related Experiment Video
Updated: Jun 3, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Morphometrical analysis of cleaning capacity using nickel-titanium rotary instrumentation associated with irrigating
Melissa Andréia Marchesan1, Marcos Porto de Arruda, Yara T Correa Silva-Sousa
1Universidade de Ribeirão Preto.
Abstract:
Variations in the internal anatomy of root canals may interfere with the success of root canal because tissue remnants may remain in the isthmus, re-entrances and ramifications of flattened root canals making instrumentation more difficult. Successful root canal treatment depends fundamentally on shaping, cleaning, disinfection and obturation. This study verified the quality of cleaning of ProFile .04 rotary technique associated with different irrigating solutions: 0.5% sodium hypochlorite, calcium hydroxide + Tergentol and 2% chlorhexidine in canals with mesio-distal flattening. Twelve human mandibular central incisors were randomly divided into 3 groups and instrumented up to ProFile 0.4 #35 file after cervical preparation, and processed histologically. After optical microscopic evaluation, statistical analysis showed that the percentage of cleaning of the three irrigating solutions was statistically different. Two-by-two comparisons classified the irrigating solutions in increasing order of cleaning: calcium hydroxide + Tergentol < chlorhexidine < 0.5% sodium hypochlorite.