Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
A new single-end mainstream CO(2) capnograph
Jiachen Yang1, Bin Wang, Chaowei Fan
1School of Electronic Information Engineering, Tianjin University, P.R. China. yangjiachen@tju.edu.cn
Abstract:
Most of the current mainstream respiratory devices for monitoring CO(2) concentration use the two-end structure combined with both reference-end and main testing-end. In this paper, we design a new single-end mainstream device for monitoring the carbon dioxide concentration that is breathed out of the human body. In this single end design, only the main testing-end will be involved. The mechanism is based on the low-cost digital processing method of blind source separation, which is used to separate the signal and then extract the reference signal. Meanwhile, in order to decrease the negative influence of device noise and the low sample precision caused by temperature drift, two steps are taken: one is wavelet denoising and the other is temperature drift compensation. These two steps are proved valid by clinical trials, thus improving the accuracy of devices.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Constant Pressure Calorimetry
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...