Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Rapidly Varying Flow01:24

Rapidly Varying Flow

Rapidly varying flow (RVF) in open channels is characterized by abrupt changes in flow depth over a short distance, with the rate of depth change relative to distance often approaching unity. These flows are inherently complex due to their transient and multi-dimensional nature, making exact analysis difficult. However, approximate solutions using simplified models provide valuable insights into their behavior.Key Features of Rapidly Varying FlowRVF is commonly observed in scenarios involving...
Uniform Depth Channel Flow01:27

Uniform Depth Channel Flow

Uniform depth channel flow keeps fluid depth consistent along channels such as irrigation canals. In natural channels, such as rivers, approximate uniform flow is often assumed. This condition occurs when the channel’s bottom slope matches the energy slope, balancing potential energy lost from gravity with head loss due to shear stress. This balance prevents depth changes along the channel length, resulting in a steady, uniform flow.Uniform flow in open channels with a constant cross-section...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Dissociable sensitivity of auditory evoked fields and 40-Hz auditory steady-state responses to spatial novelty.

Neuroscience·2026
Same author

Publisher Correction: Multi-ancestry genome-wide association analyses of refractive error augment genetic discovery and polygenic prediction.

Nature genetics·2026
Same author

Genome-Wide Meta-Analysis for High Myopia Provides Insights into Disease Mechanisms and Reveals a Causal Link to Primary Open-Angle Glaucoma.

Ophthalmology science·2026
Same author

Multi-ancestry genome-wide association analyses of refractive error augment genetic discovery and polygenic prediction.

Nature genetics·2026
Same author

Clinical performance of the multiplex solid-phase "Direct Strip PCR" for infectious uveitis: a multicenter diagnostic accuracy study.

Japanese journal of ophthalmology·2026
Same author

High-Contrast Projection Mapping under Light Field Illumination with LED Display and Aperiodic Lens Array.

IEEE transactions on visualization and computer graphics·2026
Same journal

Isolation of synovial fluid exosomes using phospholipid molecular imprinting technology and discovery of early diagnostic markers for osteoarthritis.

Analytical sciences : the international journal of the Japan Society for Analytical Chemistry·2026
Same journal

Platinum thin film-based matrix-enhanced surface-assisted laser desorption/ionization mass spectrometry imaging for improved ion yields of adrenocortical steroids.

Analytical sciences : the international journal of the Japan Society for Analytical Chemistry·2026
Same journal

Guest Editorial: next-generation analytical systems: devices and software.

Analytical sciences : the international journal of the Japan Society for Analytical Chemistry·2026
Same journal

Interfacial engineering for enantioselective electrochemical sensing of tryptophan: materials, recognition strategies, and performance benchmarking.

Analytical sciences : the international journal of the Japan Society for Analytical Chemistry·2026
Same journal

Development of a digital loop-mediated isothermal amplification using a digital polymerase chain reaction device.

Analytical sciences : the international journal of the Japan Society for Analytical Chemistry·2026
Same journal

Rapid analysis of narrow therapeutic index drugs by sonic spray ionization mass spectrometry.

Analytical sciences : the international journal of the Japan Society for Analytical Chemistry·2026
See all related articles

Related Experiment Video

Updated: Jun 3, 2026

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
08:01

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection

Published on: December 15, 2015

Air-segmented amplitude-modulated multiplexed flow analysis.

Koji Inui1, Takeshi Uemura, Takeshi Ogusu

  • 1Faculty of Pharmaceutical Sciences, Tokushima University, Tokushima, Japan.

Analytical Sciences : the International Journal of the Japan Society for Analytical Chemistry
|March 19, 2011
PubMed
Summary
This summary is machine-generated.

Air-segmentation improves sensitivity in amplitude-modulated multiplexed flow analysis by minimizing signal loss. This technique enhances the detection of analytes like food dyes and ions.

More Related Videos

A Microfluidic Model of Biomimetically Breathing Pulmonary Acinar Airways
09:39

A Microfluidic Model of Biomimetically Breathing Pulmonary Acinar Airways

Published on: May 9, 2016

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
05:11

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition

Published on: June 27, 2025

Related Experiment Videos

Last Updated: Jun 3, 2026

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
08:01

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection

Published on: December 15, 2015

A Microfluidic Model of Biomimetically Breathing Pulmonary Acinar Airways
09:39

A Microfluidic Model of Biomimetically Breathing Pulmonary Acinar Airways

Published on: May 9, 2016

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
05:11

High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition

Published on: June 27, 2025

Area of Science:

  • Analytical Chemistry
  • Flow Analysis Techniques

Background:

  • Amplitude-modulated multiplexed flow analysis (AM-MFA) is a recent technique for analyte quantification.
  • Axial dispersion can lead to amplitude damping, reducing analytical sensitivity.

Purpose of the Study:

  • To apply air-segmentation to AM-MFA to mitigate amplitude damping.
  • To investigate the impact of air-segmentation on analytical sensitivity and performance.

Main Methods:

  • Periodic variation of sample solution flow rates.
  • Merging with reagent/diluent solutions.
  • Segmentation of the merged stream using air bubbles.
  • Deaeration and subsequent absorbance measurement.
  • Quantification of analytes via absorbance wave component amplitudes.

Main Results:

  • Air-segmentation effectively limits amplitude damping caused by axial dispersion.
  • The application of air-segmentation resulted in improved analytical sensitivity.
  • The sensitivity enhancement was more significant with shorter control periods and longer flow path lengths.

Conclusions:

  • Air-segmentation is a valuable technique for enhancing the sensitivity of AM-MFA.
  • The method demonstrates effectiveness in determining various analytes, including food dye, phosphate, and nitrite ions.