Related Experiment Video
Updated: Aug 12, 2026

Assessment of Audio-Tactile Sensory Substitution Training in Participants with Profound Deafness Using the Event-Related Potential Technique
Published on: September 7, 2022
Speech perception with a single-channel cochlear implant: a comparison with a single-channel tactile device
A E Carney1, M Kienle, R T Miyamoto
1Boys Town National Institute Research Hospital, Omaha, NE 68131.
Abstract:
Suprasegmental and segmental speech perception tasks were administered to 8 patients with single-channel cochlear implants. Suprasegmental tasks included the recognition of syllable number, syllabic stress, and intonation. Segmental tasks included the recognition of vowels and consonants in three modalities: visual only, implant only, and visual + implant. Results were compared to those obtained from artificially deafened adults using a single-channel vibrotactile device. The patterns of responses for both suprasegmental and segmental tasks were highly similar for both groups of subjects, despite differences between the characteristics of the subject samples. These results suggest that single-channel sensory devices, whether they be cochlear implants or vibrotactile aids, produce similar patterns of speech perception errors, even when differences are observed in overall performance level.