Mechanism of complex fractionated electrograms recorded during atrial fibrillation in a canine model
Edward P Gerstenfeld1, Nimrod Lavi, Victor Bazan
1Section of Cardiac Electrophysiology, Division of Cardiology, Department of Medicine, University of Pennsylvania Hospital, Philadelphia, Pennsylvania, USA. edward.gerstenfeld@uphs.upenn.edu
Background:
Complex fractionated atrial electrograms (CFEs) have been described as a target during atrial fibrillation (AF) ablation; however, the mechanism leading to CFEs is poorly understood. We used noncontact mapping in a canine model of AF to determine the activation patterns in areas of CFEs.
Methods:
Sustained AF was induced in 10 canines with 10-12 weeks of atrial tachy-pacing at 440 ppm. A roving mapping catheter and noncontact multielectrode array (MEA) were deployed in the left atrium (LA). NavX software was used to construct a contact bipolar CFE LA map. The MEA was then used to reconstruct wavefront propagation in proximity to CFE regions. Wavefront propagation was assessed during three separate recording segments for each site.
Results:
There were 34 CFE regions identified (3.4/dog) and 102 noncontact CFE regional activation sequences studied. The CFE regions were stereotypically located at the junctions of (1) the left pulmonary vein (PV)/posterior LA, (2) right inferior PV/posterior LA, (3) right superior PV/anterior LA, and (4) the LA roof. The majority (47%) of CFE recordings were characterized by wavefront collision, usually between circulating LA wavefronts and entry/exit from the PVs. Thirty-eight (38%) CFE recordings were noted to be the central functional barrier of a reentrant wavefront. Ablation through CFE regions due to reentry led to AF termination and noninducibility in 3/5 animals.
Conclusions:
In this pacing-induced AF model, common causes of CFEs include: (1) wavefront collision, (2) conduction through channels of functional block, (3) reentry. The vast majority of these CFE regions were caused by wavefront collision rather than true "drivers" of AF.
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Electrophysiology of Normal Cardiac Rhythm