Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Validated method for measuring airborne concentrations of tert-butylphenols for occupational exposure assessment.

Journal of occupational health·2026
Same author

A method for simultaneously determining both the inhalable fraction and vapor concentration to assess worker exposure to tri-n-butyl phosphate.

Journal of occupational health·2025
Same author

Air sampling and analysis method to determine worker exposure levels to N-isopropyl-N'-phenyl-p-phenylenediamine.

Journal of occupational health·2025
Same author

A method for determining workers' exposure concentration to airborne nitrilotriacetic acid.

Journal of occupational health·2025
Same author

Degree of twist in the Achilles tendon interacts with its length and thickness in affecting local strain magnitude: a finite element analysis.

Frontiers in bioengineering and biotechnology·2024
Same author

Urinary benzyl alcohol and hippuric acid in workers exposed to benzyl alcohol during paint-stripping work.

Journal of occupational health·2024

Related Experiment Video

Updated: Jun 3, 2026

Assessment of the Acute Inhalation Toxicity of Airborne Particles by Exposing Cultivated Human Lung Cells at the Air-Liquid Interface
10:10

Assessment of the Acute Inhalation Toxicity of Airborne Particles by Exposing Cultivated Human Lung Cells at the Air-Liquid Interface

Published on: February 23, 2020

Determination method for xylidines in workplace air.

Akito Takeuchi1, Shinobu Yamamoto, Warren Hendricks

  • 1Osaka Occupational Health Service Center, Japan Industrial Safety and Health Association, Japan. a-takeuchi@jisha.or.jp

Journal of Occupational Health
|March 23, 2011
PubMed
Summary

A new method accurately measures xylidines (XLDs) in workplace air, aiding risk assessment. This validated technique ensures reliable personal exposure monitoring for improved worker safety.

More Related Videos

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
07:57

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector

Published on: July 25, 2014

Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry
08:23

Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry

Published on: June 14, 2018

Related Experiment Videos

Last Updated: Jun 3, 2026

Assessment of the Acute Inhalation Toxicity of Airborne Particles by Exposing Cultivated Human Lung Cells at the Air-Liquid Interface
10:10

Assessment of the Acute Inhalation Toxicity of Airborne Particles by Exposing Cultivated Human Lung Cells at the Air-Liquid Interface

Published on: February 23, 2020

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
07:57

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector

Published on: July 25, 2014

Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry
08:23

Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry

Published on: June 14, 2018

Area of Science:

  • Occupational Health
  • Analytical Chemistry
  • Environmental Monitoring

Background:

  • Xylidines (XLDs) are industrial chemicals requiring accurate workplace air monitoring for risk assessment.
  • Existing methods may lack the sensitivity or practicality for comprehensive exposure evaluation.

Purpose of the Study:

  • To develop and validate a robust method for determining xylidine levels in occupational air.
  • To establish a reliable tool for personal exposure monitoring and risk assessment in industrial settings.

Main Methods:

  • Development of an air sampler using sulfuric acid-treated glass fiber filters.
  • Extraction and derivatization of XLDs with heptafluorobutyric anhydride.
  • Analysis using gas chromatography coupled with mass spectrometry (GC-MS).

Main Results:

  • High average recoveries (83-101%) for personal exposure monitoring.
  • Excellent storage stability with over 90% recovery after 5 days refrigerated.
  • Low limit of quantitation (LOQ) of 0.600 µg/sample and good reproducibility (0.8-10.3% RSD).

Conclusions:

  • The validated method allows for 4-hour personal exposure monitoring of XLDs.
  • Effective for assessing worker exposure at concentrations relevant to the TLV-TWA.