A Coregistered Ultrasound and Photoacoustic Imaging Protocol for the Transvaginal Imaging of Ovarian Lesions
Published on: March 3, 2023
Real-time co-registration using novel ultrasound technology: ex vivo validation and in vivo applications
Eric Y Yang1, Venkateshwar R Polsani, Michael J Washburn
1Baylor College of Medicine, 6565 Fannin Street, Houston, TX 77030, USA.
Objective:
The study objective was to evaluate whether a novel global position system (GPS)-like position-sensing technology will enable accurate co-registration of images between imaging modalities. Co-registration of images obtained by different imaging modalities will allow for comparison and fusion between imaging modalities, and therefore has significant clinical and research implications. We compared ultrasound (US) and magnetic resonance imaging (MRI) scans of carotid endarterectomy (CEA) specimens using a novel position-sensing technology that uses an electromagnetic (EM) transmitter and sensors mounted on a US transducer. We then evaluated in vivo US-US and US-MRI co-registration.
Methods:
Thirteen CEA specimens underwent 3.0 Tesla MRI, after which images were uploaded to a LOGIQ E9 3D (GE Healthcare, Wauwatosa, WI) US system and registered by identifying two to three common points. A similar method was used to evaluate US-MRI co-registration in patients with carotid atherosclerosis. For carotid intima-media thickness (C-IMT) measurements, 10 volunteers underwent bilateral carotid US scans co-registered to three-dimensional US maps created on the initial visit, with a repeat scan 2 days later.
Results:
For the CEA specimens, there was a mean of 20 (standard error [SE] 2.0) frames per MRI slice. The mean frame difference, over 33 registration markers, between MRI and US scans for readers 1 and 2 was -2.82 ± 19.32 and 2.09 ± 14.68 (mean ± 95% CI) frames, respectively. The US-MRI intraclass correlation coefficients (ICCs) for the first and second readers were 0.995 and 0.997, respectively. For patients with carotid atherosclerosis, the mean US frames per MRI slice (9 [SE 2.3]) was within range of that observed with CEA specimens. Inter-visit, intra-reader, and inter-reader reproducibility of C-IMT measurements were consistently high (side-averaged ICC >0.9).
Conclusion:
Accurate co-registration between US and other modalities is feasible with a GPS-like technology, which has significant clinical and research applicability.
More Related Videos
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...