Monitoring the conjunctiva for carbon dioxide and oxygen tensions and pH during cardiopulmonary bypass
Irwin K Weiss1, Sherwin J Isenberg, David L McArthur
1Department of Pediatrics, David Geffen School of Medicine at UCLA, Mattel Children's Hospital UCLA, Los Angeles, California 90095-1752, USA. iweiss@mednet.ucla.edu
Abstract:
The purpose of this study was to measure, for the first time, multiple physiologic parameters of perfusion (pH, PCO2, PO2, and temperature) from the conjunctiva of adult patients during cardiopulmonary bypass while undergoing cardiothoracic surgery. Ten patients who underwent either intracardiac valve repair, atrial septal defect repair, or coronary artery bypass graft surgery had placement of a sensor which directly measured pH, PCO2, PO2, and temperature from the conjunctiva. Data were stratified into seven phases (0-5 minutes prior to bypass; 0-5, 6-10, and 11-15 minutes after initiation of bypass; 0-5 minutes prior to conclusion of bypass; and 0-5 and 6-10 minutes after bypass) and analyzed using a mixed model analysis.The change in conjunctival pH over the course of measurement was not statistically significant (p = .56). The PCO2 level followed a quadratic pattern, decreasing from a mean pre-bypass level of 37.7 mmHg at baseline prior to the initiation of cardiopulmonary bypass to a nadir of 33.2 mmHg, then increasing to a high of 39.4 mmHg at 6-10 minutes post bypass (p < .01). The PO2 declined from a mean pre-bypass level of 79.5 mmHg to 31.3 mmHg by 6-10 minutes post bypass and even post-bypass, it never returned to baseline values (p < .01). Temperature followed a pattern similar to PCO2 by returning to baseline levels as the patient was re-warmed following bypass (p < .01). There was no evidence of any eye injury or inflammation following the removal of the sensor. In the subjects studied, the conjunctival sensor yielded reproducible measurements during the various phases of cardiopulmonary bypass without ocular injury. Further study is necessary to determine the role of conjunctival measurements in critical settings.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.