Video instructions improve accuracy of self-measures of waist circumference compared with written instructions
Dara F McEneaney1, Susan C Lennie
1Community Dietetic Department, NHS Grampian, Westholme, Woodend Hospital Site, Queens Road, Aberdeen AB15 6LS, UK.
Objective:
To determine whether video-based instructions improve the accuracy of self-measures of waist and hip circumference compared with written instructions.
Design:
Population-based, cross-sectional study. Self-measurements of waist circumference (WC) and hip circumference (HC) of fifty-seven participants randomly allocated to receive either written instruction or video instruction were compared with those of a trained technician.
Setting:
Aberdeen, Scotland, and Brussels, Belgium, between February and April 2010.
Subjects:
Adults aged 18-62 years with a high level of English language and no prior training in anthropometry.
Results:
WC was significantly overestimated by the written method (1·75 cm bias; P = 0·007) but not the video method (0·95 cm bias; P = 0·239). HC was significantly underestimated in both written (-0·35 cm bias; P = 0·009) and video methods (-0·75 cm bias; P = 0·046). Reliability was not significantly affected by age, sex, BMI or WC. Bland-Altman plots demonstrated wide limits of agreement for WC (-6·83, 6·08 cm for written method; -10·14, 6·72 cm for video method) and HC (-12·85, 1·60 cm for written method; -10·82, 2·50 cm for video method).
Conclusions:
Video technology can support more accurate self-measurements of anthropometric data in epidemiological studies. Further research is warranted using larger and more heterogeneous samples in order that results can be generalised.
More Related Videos
05:59Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity
Published on: March 7, 2019
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...