Related Experiment Video
Updated: Jun 3, 2026

Optimization of An Air-Based Heat Management System for Dusty Particulate Matter-Covered Lithium-Ion Battery Packs
Published on: November 3, 2023
Determination of the cooling capacity for body ventilation system
1Biophysics and Biomedical Modeling Division, US Army Research Institute of Environmental Medicine, 42 Kansas Street, Natick, MA 01760, USA. xiaojiang.xu@us.army.mil
Abstract:
Body ventilation systems (BVS) are effective in reducing heat strain, but the amount of heat that a BVS removes from a human body is unclear. The purpose of this study was to propose a method for quantifying BVS cooling capacity using manikin evaluation and modeling. Cooling capacity was calculated as the product of maximum cooling potential and cooling efficiency. The maximum cooling potential is calculated as the difference in enthalpy between the air entering and exiting the BVS where the outlet air temperature is equal to skin temperature with a relative humidity of 100%. The cooling efficiency, defined as a ratio of the cooling capacity to the maximum cooling potential, can be determined through measurements on sweating thermal manikins. A BVS system was evaluated on a manikin with the ventilation fan ON (flow rate 4.7 L/s) or OFF under eleven ambient conditions. The measured cooling efficiencies were 0.31 ± 0.02 and almost constant. Using this cooling efficiency, the BVS cooling capacities at various skin temperature and ambient conditions were estimated. This two-step approach can be used to quantify BVS cooling effectiveness during physiology studies. First, the cooling efficiency is determined on sweating thermal manikins. Second, the cooling capacity is calculated from the skin temperature, ambient temperature and relative humidity. However, various factors may reduce the actual cooling provided by the BVS, and the calculated cooling capacity should be considered the upper limit for cooling.
Related Concept Videos
Heat Capacity: Problem-Solving
Determine the type of gas: The heat capacity of a gas depends on its molecular structure and the degree of freedom of its molecules. Different types of...
Respiratory Volumes and Capacities
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes and Capacities I
Heating and Cooling Curves