Related Experiment Video
Updated: Jun 3, 2026

12:28
Quantification of Vascular Parameters in Whole Mount Retinas of Mice with Non-Proliferative and Proliferative Retinopathies
Published on: March 12, 2022
Quantification of parapapillary atrophy and optic disc
Cheng-Kai Lu1, Tong Boon Tang, Augustinus Laude
1School of Engineering, Department of Psychology, The University of Edinburgh, United Kingdom.
Investigative Ophthalmology & Visual Science
|April 7, 2011
Summary
A new software tool automatically detects and quantifies parapapillary atrophy (PPA) and optic disc (OD) regions in retinal images. This computer-aided method achieves over 93% accuracy, aiding in eye screening.
Area of Science:
- Ophthalmology
- Medical Imaging
- Computer Vision
Background:
- Parapapillary atrophy (PPA) and optic disc (OD) are key indicators in retinal health.
- Accurate quantification of these regions is crucial for diagnosing and monitoring eye conditions.
- Existing methods for PPA and OD measurement can be time-consuming and subjective.
Purpose of the Study:
- To develop and validate a computer-aided tool for automatic detection and quantification of PPA and OD.
- To assess the accuracy and reliability of the proposed algorithm in measuring these retinal structures.
- To provide a novel software solution for objective PPA and OD size estimation from fundus images.
Main Methods:
- The optic disc (OD) region was segmented using a Chan-Vese model with shape constraints.
- Parapapillary atrophy (PPA) was estimated using a modified Chan-Vese approach after OD removal.
- Boundary refinement involved thresholding, scanning filters, and region-growing; dual color channels minimized artifact interference.
Main Results:
- The algorithm was tested on 94 images from 66 subjects with PPA.
- Mean accuracy for PPA and OD size estimation was 93.8% and 94.0%, respectively.
- High correlation (0.98) was observed between automated and ophthalmologist-defined measurements for both PPA and OD.
Conclusions:
- This software provides the first automated method for quantifying PPA size in retinal fundus images.
- The algorithm reliably detects and quantifies PPA and OD with high accuracy (>93%).
- Additional measurements like OD diameter may enhance its utility in eye screening programs.