Related Experiment Video
Updated: Jun 2, 2026

Uncovering Beat Deafness: Detecting Rhythm Disorders with Synchronized Finger Tapping and Perceptual Timing Tasks
Published on: March 16, 2015
Tapping in synchrony with a perturbed metronome: the phase correction response to small and large phase shifts as a
1Haskins Laboratories, New Haven, Connecticut 06511-6624, USA. repp@haskins.yale.edu
Abstract:
When tapping is paced by an auditory sequence containing small phase shift (PS) perturbations, the phase correction response (PCR) of the tap following a PS increases with the baseline interonset interval (IOI), leading eventually to overcorrection (B. H. Repp, 2008). Experiment 1 shows that this holds even for fixed-size PSs that become imperceptible as the IOI increases (here, from 400 to 1200 ms). Earlier research has also shown (but only for IOI=500 ms) that the PCR is proportionally smaller for large than for small PSs (B. H. Repp, 2002a, 2002b). Experiment 2 introduced large PSs and found smaller PCRs than in Experiment 1, at all of the same IOIs. In Experiments 3A and 3B, the author investigated whether the change in slope of the sigmoid function relating PCR and PS magnitudes occurs at a fixed absolute or relative PS magnitude across different IOIs (600, 1000, 1400 ms). The results suggest no clear answer; the exact shape of the function may depend on the range of PSs used in an experiment. Experiment 4 examined the PCR in the IOI range from 1000 to 2000 ms and found overcorrection throughout, but with the PCR increasing much more gradually than in Experiment 1. These results provide important new information about the phase correction process and pose challenges for models of sensorimotor synchronization, which presently cannot explain nonlinear PCR functions and overcorrection.
Related Concept Videos
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
Gain
Gain:
Suppose Vin is the input and Vout is the output signal to a circuit.
Phase-lead and Phase-lag Controllers
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Phase Changes
A substance melts or freezes at a temperature called its melting point and boils or condenses at its boiling point. These temperatures depend on pressure. High pressure favors the denser form of the substance, so typically, high pressure...

