Related Experiment Video
Updated: Jun 2, 2026

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Comparison of void volume, mobile phase volume and accessible volume determined from retention data for oligomers in
Mei Wang1, Jennifer Mallette, Jon F Parcher
1National Center for Natural Products Research, University of Mississippi, University, MS 38677, USA.
Abstract:
The experimental technique of mass spectrometric tracer pulse chromatography was used to determine the void volume, i.e., the total volume of eluent in the column, and the volume of eluent moving freely through the column, i.e., mobile phase volume, for a series of eluents with a C(18)-bonded RPLC column. The interstitial volume of the column was determined by size exclusion chromatography. In order to evaluate the utility of the accessible volumes determined from the retention volumes of homologous solutes, the accessible volume of the column was determined as a function of eluent composition and temperature with polystyrene and polyethylene glycol samples using Martin's Rule. Comparison of these four measured volumes indicated that the experimentally measured accessible volumes did not correspond to either the void volumes, mobile phase volumes or interstitial volumes.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Chromatographic Methods: Terminology
High-Performance Liquid Chromatography: Elution Process
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Analyte Adsorption and Distribution
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: