The reliability of a handheld wound measurement and documentation device in clinical practice
Catherine E Hammond1, Mark A Nixon
1Nurse Maude, Christchurch, New Zealand. catherineh@nursemaude.org.nz
Purpose:
The aim of this study was to evaluate the precision (intra- and interrater variability) and usability of a new handheld wound measurement device designed to measure wound surface area and depth across a range of typical wound types.
Subjects And Setting:
Raters included a doctor, a nurse, and a novice who was unfamiliar with wound care and the study equipment. Patients of nurse maude, a community-based home health organization in christchurch, new zealand, were assessed at either the wound clinic or the patient's home.
Method:
Five repeated area and depth measurements were made on 5 different wounds by the 3 raters, resulting in up to 75 area and depth measurements. The time taken to make each measurement was also recorded.
Instrument:
This study evaluated a handheld wound imaging, measurement, and documentation device (SilhouetteMobile, ARANZ Medical Limited, Christchurch, New Zealand).
Results:
Variances and coefficients of variation (CV) between raters (interrater) and within raters (intrarater) over the 5 wounds were calculated, as was the intraclass correlation coefficient. Inter- and intrarater precision for surface area was 3.2% and 2.6%, respectively, and depth 13.5% and 5.5%, respectively; intraclass correlation coefficients for area and depth were 99.76% and 98.95%, respectively. Approximately 2 minutes were required to capture photographic documentation and perform area and depth measurements. Use of the device provided practitioners and patients with immediate feedback on wound healing progress.
Conclusion:
The device was found to have low intra- and interrater variation. The photographic record and measurements can be collected in approximately 2 minutes and in a noncontact fashion. A novice user was able to use the device proficiently with 1 hour of training.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Assessing Blood pressure in the Leg
Preparation:
Uncertainty in Measurement: Reading Instruments
Uncertainty in Measurement: Accuracy and Precision
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...