Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Comparison of different statistical approaches to evaluate the orthogonality of chromatographic separations:
Ramia Al Bakain1, Isabelle Rivals, Patrick Sassiat
1Laboratoire Sciences Analytiques, Bioanalytiques et Miniaturisation UMR-CNRS-UPMC-PECSA, Ecole Supérieure de Physique et de Chimie Industrielles de la Ville de Paris, ParisTech, Paris, France.
Abstract:
Selectivity of phase system is of primary concern when designing a bidimensional chromatographic system and looking for the highest degree of orthogonality between the two separations. Several statistical or geometrical criteria can potentially be used to measure the degree of orthogonality. A comparison of eight candidate criteria has been carried out in this study. Analysis of variance (ANOVA) was used to evaluate the relevance of each criterion and its ability to reveal the significance of the influence of factors like pH, stationary phase, and organic modifier. Experimentally, a set of 32 chromatographic systems was evaluated by the same generic gradient with 63 probe solutes, likely to be present in biological and/or environmental samples and covering a wide range of physico-chemical properties: acidic, basic and neutral compounds with different pKa, molecular mass and hydrophobicity (logP). Each chromatographic system was defined by the nature of the stationary phase (8 different silica or grafting chemistries), the pH of the aqueous fraction of the mobile phase (2.5 or 7.0) and the nature of the organic modifier (acetonitrile or methanol). The orthogonality of the 496 couples of chromatographic systems was evaluated and ranked using the eight different approaches: the three correlation coefficients (Pearson, Spearman and Kendall), two geometric criteria characterizing the coverage of the 2D separation space, Slonecker's information similarity and two chi-square statistics of independence between normalized retention times. In fact, there were only seven distinct criteria, since we established the analytical equivalence between the rankings with the likelihood ratio statistics and Slonecker's information similarity. Kendall's correlation coefficient appeared to be the best measure of orthogonality since, according to ANOVA, it exhibited the highest sensitivity to all experimental factors. The chi-square measures, and hence Slonecker's information similarity, performed equally well provided the discretization of the separation space was carried out appropriately. Finally, from the compared study of the factors acting upon orthogonality carried out by ANOVA, it is possible to draw the conclusion that the pH of the mobile phases has the highest impact on the selectivity followed by the type of stationary phase and finally by the organic modifier.
More Related Videos
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: