Ultrasound dilution: an accurate means of determining cardiac output in children
Ivory Crittendon1, William J Dreyer, Jamie A Decker
1Section of Pediatric Cardiology-Department of Pediatrics, Baylor College of Medicine, Texas Children's Hospital, Houston, TX, USA. ivory.crittendon@gmail.com
Background:
Cardiac output is a useful measure of myocardial performance. Cardiac output monitoring is frequently performed in critically ill adults to guide physicians' treatment strategies. However, standard methods of determining cardiac output in children are not without risk and can be problematic secondary to their invasive nature and other technical problems. The COstatus system (Transonic Systems, NY), which is based on ultrasound dilution technology, works off in situ catheters and uses an innocuous indicator to allow for routine measurements of cardiac output and blood volumes in pediatric patients. The purpose of this study was to validate cardiac output measured by the COstatus system with those obtained by the clinical standard technique of pulmonary artery thermodilution.
Methods:
This was a prospective evaluation performed at a single institution. Any child with a structurally normal heart undergoing hemodynamic evaluation in the cardiac catheterization laboratory was included. A prograde right heart catheterization was performed, and cardiac output was first determined by using the pulmonary artery thermodilution technique. Thermodilution results were then compared with cardiac output measurements obtained using the COstatus system. The results were analyzed by standard correlation, Bland-Altman, and Critchley and Critchley analyses.
Results:
Twenty-eight patients were evaluated with a median age of 8 yrs and a median weight of 31 kg. The mean thermodilution cardiac index = 3.18 L/min (± 1.35 L/min), and the mean COstatus system cardiac index = 3.17 L/min (± 1.31 L/min). Standard Pearson correlation tests revealed an excellent correlation coefficient of 0.95 (p < .0001). Bland-Altman analysis revealed good clinical agreement with a mean difference of -0.004 L/min with a precision of 0.8 L/min at 2 SD. A percentage error of 25.4% was noticed in this study, which is less than the clinically acceptable limit.
Conclusion:
The ultrasound dilution technique of determining cardiac output using the COstatus system provides a less invasive method than the traditional pulmonary artery thermodilution for accurately determining cardiac output in children. This is the first validation of the COstatus system in pediatric patients. Further studies are required to establish its accuracy in pediatric patients with cardiac shunts and other hemodynamically unstable conditions.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...