Related Experiment Videos
Device-Patient Interface Air Leaks During Noninvasive Ventilation: Single-Center Pediatric Experience and Outcomes,
Nathalie El-Hawli1, Francis-Olivier Beauchamp1,2, Sandrine Essouri1,2
1Faculty of Medicine, Université de Montréal, Montréal, QC, Canada.
Objectives:
Air leaks are common during noninvasive ventilation (NIV) of children in the PICU. We aimed to describe our experience with NIV and study the association between the occurrence of air leaks and clinical parameters, and the median (95% CI) of ventilator-free days (VFDs).
Design:
Single-center retrospective cohort, 2018-2023, identified in local health databases.
Setting:
A quaternary children's center PICU in Montréal, Quebec, Canada.
Patients:
All pediatric patients admitted to the PICU and ventilated with a dual-limb NIV circuit (2018-2023). Only the first 6 hours of NIV per admission were analyzed; repeated admissions were included as separate encounters.
Interventions:
None.
Measurements And Main Results:
Among 1460 encounters (1292 distinct patients), the median (interquartile range [IQR]) of air leak occurrence was 74% (IQR, 62-83%). Younger age was associated with a higher occurrence of air leaks (p < 0.001): 79% (IQR, 71-86%) in 681 infants 0-6 months old vs. 70% (IQR, 56-82%) in 328 older infants and toddlers 7-24 months old (n = 328, 22%) vs. 66% (IQR, 49-78%) in 451 preschool and school-aged children older than 24 months. A 10% increase in median air leak occurrence during the first 6 hours of NIV was associated with 0.6 fewer VFDs (slope estimate, -0.06 [95% CI, -0.10 to -0.01]). Lower air leaks were associated with higher peak airway pressures (slope estimate, -0.79 [95% CI, -1.44 to -0.15]), higher respiratory rate (slope estimate, -0.19 [95% CI, -0.35 to -0.03]), and greater weight (slope estimate, -0.40 [95% CI, -0.54 to -0.26]).
Conclusions:
In our center, 2018-2023, high air leaks were frequent during NIV and associated with fewer VFDs. As a potentially modifiable factor, further prospective research is needed to assess the impact of air leaks on outcomes.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Suctioning the Nasopharyngeal Airway
Equipment Required