Related Experiment Video
Updated: May 6, 2026

A Pleural Effusion Model in Rats by Intratracheal Instillation of Polyacrylate/Nanosilica
Published on: April 12, 2019
Correlation of M-L, Leinfelder, and USPHS clinical evaluation techniques for wear
D F Taylor1, S C Bayne, J R Sturdevant
1School of Dentistry, University of North Carolina, Chapel Hill.
Abstract:
Most recent clinical research studies on wear of posterior composite restorations have used the USPHS and Leinfelder measuring techniques. New studies are adopting the Moffa-Lugassy (M-L) technique. However, to date there has been no means of comparing results of the different techniques. The objective of this study was to correlate the M-L scale wear values to Leinfelder scale wear values and to USPHS scale alfa-bravo transitions, so that data can be pooled across studies for comparisons. M-L evaluations were made for 221 restorations previously evaluated by the USPHS and Leinfelder methods. The M-L wear values were determined as the mean of three independent evaluators' values. At the USPHS alfa-bravo transition, the mean Leinfelder wear value was 192 microns, and the mean M-L value was 97 microns. The correlation coefficient for the linear regression of M-L values vs. Leinfelder values was 0.87. The scales were linearly related, with a slope of 0.52. The average values for M-L readings of wear were statistically different and approximately half the Leinfelder values.