Updated: Jun 2, 2026

High Throughput Microfluidic Rapid and Low Cost Prototyping Packaging Methods
07:51

High Throughput Microfluidic Rapid and Low Cost Prototyping Packaging Methods

Published on: December 23, 2013

Multiscale variation-aware techniques for high-performance digital microfluidic lab-on-a-chip component placement.

Chen Liao1, Shiyan Hu

  • 1Department of Electrical and Computer Engineering, Michigan Technological University, Houghton, MI 49931, USA. cliao@mtu.edu

IEEE Transactions on Nanobioscience
|April 23, 2011
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Intracellular acidification by microbiota-derived valeric acid facilitates trans-kingdom ecology limiting Candida parapsilosis colonization.

Cell host & microbe·2026
Same author

Gut Commensals Regulate the Intestinal Kynurenine Pathway.

bioRxiv : the preprint server for biology·2026
Same author

A microbiota-derived bile acid overcomes antibiotic-induced hyporesponsiveness to immune checkpoint therapy by enhancing CD8 <sup>+</sup> T cell antitumor immunity.

bioRxiv : the preprint server for biology·2026
Same author

Polystyrene microplastics disrupt the blood-testis barrier via CEBPB-driven lysosomal autophagy and induce ferroptosis-like injury in human sperm, compromising embryo development.

Journal of hazardous materials·2026
Same author

Single-cell and spatial transcriptomic analysis reveals PAX5's role and regulatory mechanisms in gastric adenocarcinoma lymph node metastasis.

Journal of translational medicine·2026
Same author

Nanoscale greenhouse effect for promoting solar-driven CO<sub>2</sub> reduction with water to CH<sub>4</sub>.

Nature communications·2026
Same journal

Investigating Effect of Dimensional Variance on Separation of Glomerular Ultrafiltrate in a Microfluidic Environment.

IEEE transactions on nanobioscience·2026
Same journal

Green synthesis of multifunctional ZnFe<sub>2</sub>O<sub>4</sub>-MWCNT-Cellulose acetate nanocomposite for peroxidase enzyme immobilization.

IEEE transactions on nanobioscience·2026
Same journal

IoT-Enabled SnO₂-Based Humidity Sensor for Real-Time Monitoring in Neonatal Incubators.

IEEE transactions on nanobioscience·2026
Same journal

Electrokinetic and Antibiofilm Effects of Silver Nanoparticles Combined with Imipenem Against multidrug-resistant of Klebsiella pneumoniae.

IEEE transactions on nanobioscience·2026
Same journal

Bio-inspired Optofluidic Molecular Communication with Photothermally Actuated Microrobot Swarms.

IEEE transactions on nanobioscience·2026
Same journal

Nanostructured ZnO Thin Film-Based Enzymatic Biosensor for Sensitive Acetylcholine Detection in Neurological Applications.

IEEE transactions on nanobioscience·2026
See all related articles

This study introduces a computer-aided design (CAD) method for microfluidic lab-on-a-chip component placement. The novel technique significantly reduces completion time and ensures design constraints are met, even with process variations.

Area of Science:

  • Microfluidics
  • Biotechnology
  • Computer-Aided Design (CAD)

Background:

  • Traditional biochemical lab procedures are costly and time-consuming.
  • Increasing complexity of microfluidic lab-on-a-chip devices necessitates advanced design tools.
  • Computer-aided design (CAD) is crucial for efficient digital microfluidic lab-on-a-chip layout.

Purpose of the Study:

  • To propose a multiscale variation-aware optimization technique for lab-on-a-chip component placement.
  • To minimize the overall completion time of lab-on-a-chip operations.
  • To ensure nonoverlapping, resource, and scheduling constraints are satisfied during placement.

Main Methods:

  • Integer linear programming (ILP) was employed for optimization.
  • A multiscale approach was developed to account for variations.

More Related Videos

Scalable Fabrication of Stretchable, Dual Channel, Microfluidic Organ Chips
14:44

Scalable Fabrication of Stretchable, Dual Channel, Microfluidic Organ Chips

Published on: October 20, 2018

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

Related Experiment Videos

Last Updated: Jun 2, 2026

High Throughput Microfluidic Rapid and Low Cost Prototyping Packaging Methods
07:51

High Throughput Microfluidic Rapid and Low Cost Prototyping Packaging Methods

Published on: December 23, 2013

Scalable Fabrication of Stretchable, Dual Channel, Microfluidic Organ Chips
14:44

Scalable Fabrication of Stretchable, Dual Channel, Microfluidic Organ Chips

Published on: October 20, 2018

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

  • The technique focuses on determining optimal physical locations and operation start times.
  • Main Results:

    • The proposed technique significantly outperforms the state-of-the-art, reducing completion time by up to 65.9% without considering variations.
    • When variations are considered, the variation-aware technique maintains yield constraints, with only a 7.7% increase in completion time.
    • Variation-unaware designs showed an average yield of only 2% under variation conditions.

    Conclusions:

    • The developed variation-aware optimization technique is effective for lab-on-a-chip component placement.
    • This approach successfully addresses design constraints and minimizes completion time in complex microfluidic systems.
    • The method offers a robust solution for fabricating reliable microfluidic devices despite manufacturing variations.