Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Four-dimensional computed tomography pulmonary ventilation images vary with deformable image registration algorithms
Tokihiro Yamamoto1, Sven Kabus, Tobias Klinder
1Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305-5847, USA. tokihiro@stanford.edu
Purpose:
A novel pulmonary ventilation imaging technique based on four-dimensional (4D) CT has advantages over existing techniques and could be used for functional avoidance in radiotherapy. There are various deformable image registration (DIR) algorithms and two classes of ventilation metric that can be used for 4D-CT ventilation imaging, each yielding different images. The purpose of this study was to quantify the variability of the 4D-CT ventilation to DIR algorithms and metrics.
Methods:
4D-CT ventilation images were created for 12 patients using different combinations of two DIR algorithms, volumetric (DIR(vol)) and surface-based (DIR(sur)), yielding two displacement vector fields (DVFs) per patient (DVF(voI) and DVF(sur)), and two metrics, Hounsfield unit (HU) change (V(HU)) and Jacobian determinant of deformation (V(Jac)), yielding four ventilation image sets (V(HU)(vol), V(HU)(sur), V(Jac)(voI), and V(Jac)(sur). First DVF(vol) and DVF(sur) were compared visually and quantitatively to the length of 3D displacement vector difference. Second, four ventilation images were compared based on voxel-based Spearman's rank correlation coefficients and coefficients of variation as a measure of spatial heterogeneity. V(HU)(vol) was chosen as the reference for the comparison.
Results:
The mean length of 3D vector difference between DVF(vol) and DVF(sur) was 2.0 +/- 1.1 mm on average, which was smaller than the voxel dimension of the image set and the variations. Visually, the reference V(HU)(vol) demonstrated similar regional distributions with V(HU)(sur); the reference, however, was markedly different from V(Jac)(vol) and V((Jac)(sur). The correlation coefficients of V(HU)(vol) with V(HU)(sur), V(Jac)(vol) and V(Jac)(sur) were 0.77 +/- 0.06, 0.25 +/- 0.06 and 0.15 +/- 0.07, respectively, indicating that the metric introduced larger variations in the ventilation images than the DIR algorithm. The spatial heterogeneities for V(HU)(vol), 'V(HU)(sur), V(Jac)(vol), and V(Jac)(sur) were 1.8 +/- 1.6, 1.8 +/- 1.5 (p = 0. 85), 0.6 +/- 0.2 (p = 0.02), and 0.7 +/- 0.2 (p = 0.03), respectively, also demonstrating that the metric introduced larger variations.
Conclusions:
4D-CT pulmonary ventilation images vary widely with DIR algorithms and metrics. Careful physiologic validation to determine the appropriate DIR algorithm and metric is needed prior to its applications.
More Related Videos
Related Concept Videos
Imaging Studies III: Computed Tomography
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...