An Intra-Tissue Radiometry Microprobe for Measuring Radiance In Situ in Living Tissue
Published on: June 2, 2023
Application of a scattered-light radiometric power meter
James N Caron1, Gregory P DiComo, Antonio C Ting
1Research Support Instruments, 4325-B Forbes Boulevard, Lanham, Maryland 20706, USA. Caron@RSImd.com
Abstract:
The power measurement of high-power continuous-wave laser beams typically calls for the use of water-cooled thermopile power meters. Large thermopile meters have slow response times that can prove insufficient to conduct certain tests, such as determining the influence of atmospheric turbulence on transmitted beam power. To achieve faster response times, we calibrated a digital camera to measure the power level as the optical beam is projected onto a white surface. This scattered-light radiometric power meter saves the expense of purchasing a large area power meter and the required water cooling. In addition, the system can report the power distribution, changes in the position, and the spot size of the beam. This paper presents the theory of the scattered-light radiometric power meter and demonstrates its use during a field test at a 2.2 km optical range.