Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometers01:16

Mass Spectrometers

This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Food waste in European Households: A Meta-Analysis of behavioural drivers and quantitative trends.

Waste management (New York, N.Y.)·2026
Same author

Dosing parameters for grafting human neural stem cells into sites of spinal cord injury.

Experimental neurology·2025
Same author

Optimising H<sub>2</sub>O<sub>2</sub> digestion and quantifying microplastics in sediment and pacific oyster (Crassostrea gigas) samples.

Marine pollution bulletin·2025
Same author

Correction: Targeting ADAM-17 with an inhibitory monoclonal antibody has antitumour effects in triple-negative breast cancer cells.

British journal of cancer·2025
Same author

In Vitro Accuracy of Digital Versus Conventional Workflows for Complete-Arch Implant- Supported Frameworks-A Scoping Review.

The International journal of prosthodontics·2024
Same author

An improved method for generating human spinal cord neural stem cells.

Experimental neurology·2024
Same journal

Compressed multi-scale entropy and its application in mechanical fault diagnosis.

The Review of scientific instruments·2026
Same journal

Bidirectional drive and multi-resolution adjustment across frequency bands in inertial impact piezoelectric motors via multimodal resonant vibration.

The Review of scientific instruments·2026
Same journal

A magnetic field sensor based on flaky Terfenol-D material and dual fiber grating.

The Review of scientific instruments·2026
Same journal

A novel E-field eight-way cavity combiner for high-power S-band applications.

The Review of scientific instruments·2026
Same journal

Constant radius blade spring suspended bench for vibration isolation.

The Review of scientific instruments·2026
Same journal

Qualification of infrared optical fibers and emitters for a spectrometer for in situ planetary exploration: Results from the TRIS (TRansmission and Illumination System) project.

The Review of scientific instruments·2026
See all related articles

Related Experiment Video

Updated: Jun 2, 2026

Sample Preparation for Probe Electrospray Ionization Mass Spectrometry
05:47

Sample Preparation for Probe Electrospray Ionization Mass Spectrometry

Published on: February 19, 2020

A comb-sampling method for enhanced mass analysis in linear electrostatic ion traps.

J B Greenwood1, O Kelly, C R Calvert

  • 1Centre for Plasma Physics, School of Mathematics and Physics, Queen's University Belfast, Belfast BT7 1NN, United Kingdom. j.greenwood@qub.ac.uk

The Review of Scientific Instruments
|May 3, 2011
PubMed
Summary
This summary is machine-generated.

A new algorithm, CHIMERA (Comb-sampling for High-resolution IMpulse-train frequency ExtRAaction), enhances spectral analysis for ion trap mass spectrometry. It offers significantly higher resolution and clearer spectra compared to traditional Fourier analysis.

More Related Videos

An Efficient Sample Preparation Method to Enhance Carbohydrate Ion Signals in Matrix-assisted Laser Desorption/Ionization Mass Spectrometry
07:12

An Efficient Sample Preparation Method to Enhance Carbohydrate Ion Signals in Matrix-assisted Laser Desorption/Ionization Mass Spectrometry

Published on: July 29, 2018

Analyzing Protein Architectures and Protein-Ligand Complexes by Integrative Structural Mass Spectrometry
07:33

Analyzing Protein Architectures and Protein-Ligand Complexes by Integrative Structural Mass Spectrometry

Published on: October 15, 2018

Related Experiment Videos

Last Updated: Jun 2, 2026

Sample Preparation for Probe Electrospray Ionization Mass Spectrometry
05:47

Sample Preparation for Probe Electrospray Ionization Mass Spectrometry

Published on: February 19, 2020

An Efficient Sample Preparation Method to Enhance Carbohydrate Ion Signals in Matrix-assisted Laser Desorption/Ionization Mass Spectrometry
07:12

An Efficient Sample Preparation Method to Enhance Carbohydrate Ion Signals in Matrix-assisted Laser Desorption/Ionization Mass Spectrometry

Published on: July 29, 2018

Analyzing Protein Architectures and Protein-Ligand Complexes by Integrative Structural Mass Spectrometry
07:33

Analyzing Protein Architectures and Protein-Ligand Complexes by Integrative Structural Mass Spectrometry

Published on: October 15, 2018

Area of Science:

  • Analytical Chemistry
  • Spectroscopy
  • Physics

Background:

  • Frequency analysis of ion bunch oscillations in linear electrostatic ion traps is crucial for high-resolution mass spectrometry.
  • Current Fourier transform methods face limitations in spectral resolution and harmonic interference.

Purpose of the Study:

  • To introduce and validate the CHIMERA algorithm for improved spectral information extraction from impulse-train signals.
  • To enhance the resolution and accuracy of mass spectrometry performed on ion traps.

Main Methods:

  • Developed the CHIMERA algorithm utilizing a comb function for frequency coefficient generation.
  • Applied the algorithm to both synthetic and real ion trap data.
  • Compared CHIMERA performance against traditional Fourier transform analysis.

Main Results:

  • CHIMERA demonstrated superior data matching compared to sinusoidal functions used in Fourier transforms.
  • Mass spectra generated by CHIMERA showed an order of magnitude higher resolution than Fourier frequencies.
  • The new method effectively eliminated large contributions from harmonic frequency components.

Conclusions:

  • The CHIMERA algorithm represents a significant advancement in frequency analysis for ion trap mass spectrometry.
  • It provides a more precise and higher-resolution method for spectral analysis, particularly when ions are localized and data is acquired simultaneously.
  • CHIMERA overcomes key limitations of Fourier analysis, offering clearer and more resolved mass spectra.