Should the placement of carbon monoxide (CO) detectors be influenced by CO's weight relative to air?
Neil B Hampson1, Todd G Courtney, James R Holm
1Center for Hyperbaric Medicine, Virginia Mason Medical Center, Seattle, WA 98101, USA.
Background:
Numerous states and localities have recently passed legislation mandating the installation and use of residential carbon monoxide (CO) detectors/alarms. Interestingly, there seems to be confusion about the optimal placement, if any, of CO alarms inside the home.
Objectives:
It was the goal of this study to demonstrate the behavior of CO in air and to help provide a data-based recommendation for CO alarm placement.
Methods:
CO was calculated to be slightly lighter than air. An 8-foot-tall airtight Plexiglas chamber was constructed and CO monitors placed within at the top, middle, and bottom. CO test gas (15 L, 3000 parts per million) was infused at each of the three heights in different trials and CO levels measured over time.
Results:
Contrary to a significant amount of public opinion, CO did not layer on the floor, float at the middle of the chamber, or rise to the top. In each case, the levels of CO equalized throughout the test chamber. It took longer to equalize when CO was infused at the top of the chamber than the bottom, but levels always became identical with time.
Conclusions:
As would have been predicted by the Second Law of Thermodynamics, CO infused anywhere within the chamber diffused until it was of equal concentration throughout. Mixing would be even faster in the home environment, with drafts due to motion or temperature. It would be reasonable to place a residential CO alarm at any height within the room.
More Related Videos
Related Concept Videos
Center of Gravity
Center of Gravity
To determine its location, the principle of moments can be utilized by dividing the object into...
Other Factors Affecting Respiration Centers
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical level,...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated. Under...
Measurement of Air Content in Concrete
The pressure method,...