Related Experiment Video
Updated: Jun 2, 2026

Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
An LC-MS/MS procedure for the quantification of naproxen in human plasma: development, validation, comparison with
Paul W Elsinghorst1, Martina Kinzig, Michael Rodamer
1IBMP-Institute for Biomedical and Pharmaceutical Research, Nürnberg-Heroldsberg, Germany.
Abstract:
A sensitive, precise and accurate quantitative LC-MS/MS method for the measurement of naproxen in human plasma was developed and completely validated according to current FDA and EMA guidelines. The new method employs acetonitrile protein precipitation for sample preparation and uses ketoprofen as the internal standard. Suitability of the new assay was assessed in comparison with 36 reported bioanalytical assays and the pharmacokinetic results obtained by the new method were compared to 11 reported studies in humans. The principal advantage of this LC-MS/MS method is the simultaneous achievement of high absolute recovery (90.0±3.6%), acceptable sensitivity (lower limit of quantitation of 0.100 μg/mL), high inter-day precision (CV≤9.4%), high analytical recovery (between 94.4 and 103.1%), and excellent linearity over the concentration range 0.100-50.0 μg/mL (r(2)≥0.998) combined with a short run time of only 2 min.