Related Experiment Video
Updated: Jun 2, 2026

A General Method for Detecting Nitrosamide Formation in the In Vitro Metabolism of Nitrosamines by Cytochrome P450s
Published on: September 25, 2017
Determination of nitrogen mustard hydrolysis products in rat urine samples using GC-MS
1Department of Medical CBRN Defense, Gulhane Military Medical Academy, Etlik, Ankara, Turkey.
Abstract:
A gas chromatographic-mass spectrometric method was developed, validated and demonstrated by measuring the levels of nitrogen mustard hydrolysis products in the urine collected from dosed rats. The recovery values for trimethylsilyl derivatives of EDEA and MDEA are between 82-95% and 88-112%, respectively. In vivo studies performed by using three different doses (0.5 mg/kg, 1.0 mg/kg, and 2.0 mg/kg) of HN2 base of nitrogen mustard. MDEA concentrations were between 43.1-232.2 ng/mL. The limit of detection (S/N = 3) values are 2.5 ng/mL and 1.6 ng/mL for EDEA and MDEA, respectively, and the precision of the method in terms of RSD is between 5-8%.