Related Experiment Video
Updated: Jun 2, 2026

Diffusion Imaging in the Rat Cervical Spinal Cord
Published on: April 7, 2015
Toward an optimal distribution of b values for intravoxel incoherent motion imaging
Andreas Lemke1, Bram Stieltjes, Lothar R Schad
1Department of Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany. Andreas.Lemke@medma.uni-heidelberg.de
Abstract:
The intravoxel incoherent motion (IVIM) theory provides a framework for the separation of perfusion and diffusion effects in diffusion-weighted imaging (DWI). To measure the three free IVIM parameters, DWIs with several diffusion weightings b must be acquired. To date, the used b value distributions are chosen heuristically and vary greatly among researchers. In this work, optimal b value distributions for the three parameter fit are determined using Monte-Carlo simulations for the measurement of a low, medium and high IVIM perfusion regime. The first 16 b values of a b value distribution, which was optimized to be appropriate for all three regimes, are {0, 40, 1000, 240, 10, 750, 90, 390, 170, 10, 620, 210, 100, 0, 530 and 970} in units of seconds per square meter. This distribution performed well for all organs and outperformed a distribution frequently used in the literature. In case of limited acquisition time, the b values should be chosen in the given order, but at least 10 b values should be used for current clinical settings. The overall parameter estimation quality depends strongly and nonlinearly on the signal-to-noise ratio (SNR): it is essential that the SNR is considerably higher than a critical SNR. This critical SNR is about 8 for medium and high IVIM perfusion and 50 for the low IVIM perfusion regime. Initial in vivo IVIM measurements were performed in the abdomen and were in keeping with the numerically simulated results.
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

