Related Concept Videos

Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan01:13

Radiological Investigation III: Pulmonary Angiogram and PET Scan

Radiological investigations are paramount in the diagnosis and management of various pulmonary diseases. Two essential investigations are the Pulmonary Angiogram and the Positron Emission Tomography (PET) Scan.
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Dose Prediction in Proton Cancer Therapy based on Density Maps from Dual-energy CT Using Joint Statistical Image Reconstruction.

Proceedings of SPIE--the International Society for Optical Engineering·2025
Same author

Accurate Proton Stopping Power Images Reconstructed using Joint Statistical Dual Energy CT: Experimental Verification and Impact of Fan-Beam CT Scatter.

Proceedings of SPIE--the International Society for Optical Engineering·2025
Same author

Development of a Prototype AWSM-PET Device for Augmented Whole-Body PET Imaging and Initial Human Study.

Journal of nuclear medicine : official publication, Society of Nuclear Medicine·2025
Same author

Derivation of tissue properties from basis-vector model weights for dual-energy CT-based Monte Carlo proton beam dose calculations.

Biomedical physics & engineering express·2025
Same author

Derivation of Tissue Properties from Basis-Vector Model Weights for Dual-Energy CT-Based Monte Carlo Proton Beam Dose Calculations.

ArXiv·2025
Same author

A data-driven approach for spatial alignment of PET add-on detectors with sub-millimeter accuracy.

Physics in medicine and biology·2025

Related Experiment Video

Updated: Jun 2, 2026

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
10:21

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function

Published on: August 8, 2019

Compton Scattering in Clinical PET/CT With High Resolution Half Ring PET Insert Device.

Sergey A Komarov1, Heyu Wu, Daniel B Keesing

  • 1Radiology Department, Washington University in St. Louis, St. Louis, MO 63130 USA.

IEEE Transactions on Nuclear Science
|September 28, 2011
PubMed
Summary
This summary is machine-generated.

Integrating a high-resolution PET insert into conventional PET systems requires accurate scatter correction. The Single Scatter Simulation (SSS) algorithm effectively estimates scatter, improving image quality in combined PET/CT scanners.

More Related Videos

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
11:09

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals

Published on: December 16, 2022

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
09:21

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images

Published on: February 18, 2015

Related Experiment Videos

Last Updated: Jun 2, 2026

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
10:21

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function

Published on: August 8, 2019

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
11:09

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals

Published on: December 16, 2022

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
09:21

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images

Published on: February 18, 2015

Area of Science:

  • Medical Imaging
  • Nuclear Medicine
  • Biomedical Engineering

Background:

  • High-resolution PET inserts enhance image quality but introduce significant attenuation and scatter.
  • Conventional PET systems require robust corrections to utilize all coincidence events with inserts.

Purpose of the Study:

  • To evaluate the effectiveness of scatter correction methods for PET systems with high-resolution inserts.
  • To assess the Single Scatter Simulation (SSS) algorithm's accuracy in estimating scatter contributions.

Main Methods:

  • Monte Carlo simulations were used to model scatter in hypothetical and existing PET systems with inserts.
  • The Single Scatter Simulation (SSS) algorithm was implemented and validated against simulation data.
  • SSS was applied to estimate scatter in a clinical PET/CT scanner with a prototype PET insert.

Main Results:

  • SSS demonstrated good agreement with Monte Carlo simulated scatter.
  • The algorithm accurately estimated scatter contributions in a clinical setting with a PET insert.
  • Scatter correction is crucial for optimizing image quality in combined PET/CT systems.

Conclusions:

  • The Single Scatter Simulation (SSS) algorithm is applicable for scatter estimation in clinical PET/CT scanners with high-resolution inserts.
  • Accurate scatter correction is essential for maximizing the benefits of PET insert technology.
  • This work validates a method to improve quantitative accuracy in advanced PET imaging.