Related Experiment Video
Updated: Jun 2, 2026

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
Published on: November 23, 2019
Reliability of the assessment of lower limb torsion using computed tomography: analysis of five different techniques
Emmanouil Liodakis1, Iosifina Doxastaki, Kongfai Chu
1Trauma Department, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany. manoliodakis@yahoo.gr
Objective:
Various methods have been described to define the femoral neck and distal tibial axes based on a single CT image. The most popular are the Hernandez and Weiner methods for defining the femoral neck axis and the Jend, Ulm, and bimalleolar methods for defining the distal tibial axis. The purpose of this study was to calculate the intra- and interobserver reliability of the above methods and to determine intermethod differences.
Methods:
Three physicians separately measured the rotational profile of 44 patients using CT examinations on two different occasions. The average age of patients was 36.3 ± 14.4 years, and there were 25 male and 19 female patients. After completing the first two sessions of measurements, one observer chose certain cuts at the levels of the femoral neck, femoral condylar area, tibial plateau, and distal tibia. The three physicians then repeated all measurements using these CT cuts.
Results:
The greatest interclass correlation coefficients were achieved with the Hernandez (0.99 intra- and 0.93 interobserver correlations) and bimalleolar methods (0.99 intra- and 0.92 interobserver correlations) for measuring the femoral neck and distal tibia axes, respectively. A statistically significant decrease in the interobserver median absolute differences could be achieved through the use of predefined CT scans only for measurements of the femoral condylar axis and the distal tibial axis using the Ulm method. The bimalleolar axis method underestimated the tibial torsion angle by an average of 4.8° and 13° compared to the Ulm and Jend techniques, respectively.
Conclusions:
The methods with the greatest inter- and intraobserver reliabilities were the Hernandez and bimalleolar methods for measuring femoral anteversion and tibial torsion, respectively. The high intermethod differences make it difficult to compare measurements made with different methods.
More Related Videos
08:15Three-Dimensional Preoperative Virtual Planning in Derotational Proximal Femoral Osteotomy
Published on: February 17, 2023
06:28Anterior Cruciate Ligament Transection and Synovial Fluid Lavage in a Rodent Model to Study Joint Inflammation and Posttraumatic Osteoarthritis
Published on: September 2, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography