Related Experiment Video
Updated: Jun 2, 2026

A Semi-Automated and Reproducible Biological-Based Method to Quantify Calcium Deposition In Vitro
Published on: June 2, 2022
Comparison of vascular calcification scoring systems using plain radiographs to predict vascular stiffness in
Hajeong Lee1, Young-Hwan Hwang, Ji Yong Jung
1Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea.
Aim:
Vascular stiffness is associated with cardiovascular mortality in dialysis patients and related with vascular calcification and microvascular inflammation. The objective of this study is to compare predictability of two different vascular calcification scoring systems using plain radiographs in peritoneal dialysis (PD) patients.
Methods:
Vascular stiffness was represented by heart-to-femoral pulse wave velocity (hfPWV) in our 79 PD patients. Peripheral vascular calcification score (PVCS) and abdominal aortic calcification score (AACS) were measured from plain radiographs. Microvascular inflammation was represented by peritoneal protein clearance (PPC). Regression analysis and the receiver operating characteristic (ROC) curve analysis were used for analysis.
Results:
The hfPWV revealed correlation with PVCS and AACS independently. In the ROC curve analysis, area under the curve (AUC) of PVC score was 0.7119 (P = 0.006), and AUC of AACS were 0.6960 (P = 0.011). After multiple linear regression analysis, PVCS remained as a predictor of vascular stiffness (R(2) = 0.579, β = 0.210, P = 0.038). The combination of PVCS and PPC exhibited a trend toward better predictability for vascular stiffness (AUC 0.7738, P = 0.001) than any of the two parameters alone.
Conclusion:
It is assumed that the PVCS system is more predictable for vascular stiffness in our study. Moreover, the combination of PVCS and PPC might be more useful as a screening test for vascular stiffness.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

