[The acquisition and analysis of heart sound signals based on DSP]
1College of Computer & Information Engineering, Beijing Technology and Business University, Beijing 100048, China. xingsuxia@163.com
Abstract:
Heart sound signals acquisition is the primary basis for achieving non-invasive diagnosis of coronary heart disease. In this paper, a digital signal processor (DSP)-based on miniaturized circuit of heart sound signals acquisition and analysis platform was designed to achieve the functions of filtering, collecting, processing, displaying and the communicating with PC. With the self-developed experimental platform, we collected 228 cases of heart sounds of clinical data, and processed the signals using de-noising method with wavelet transform. These experimental results indicated that the db6 wavelet has the most obvious de-noising effect among the four most commonly used wavelets, i.e., haar, db6, sym8, and coif5. One wavelet at different levels possessed different de-noising effects, with level-5 db6 decomposition obtaining the most desirable result.
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: