Related Experiment Video
Updated: Jun 1, 2026

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Low-kilovoltage, high-tube-current MDCT of liver in thin adults: pilot study evaluating radiation dose, image
Takeshi Nakaura1, Kazuo Awai, Seitaro Oda
1Department of Diagnostic Radiology, Amakusa Medical Center, Kameba 854-1, Amakusa, Kumamoto 863-0046, Japan. kff00712@nifty.com
Objective:
The purpose of our study was to evaluate the effect of a low tube voltage-high tube current-time product technique for portal phase abdominal CT of thin adults.
Subjects And Methods:
This study included 25 patients who had undergone portal phase abdominal CT at 120 kVp in the preceding 6 months. All were scanned using 80 kVp and high tube-current time products. We assessed the estimated effective dose (ED), image noise, attenuation, contrast-to-noise ratio (CNR), and figure of merit of the liver and portal vein. Two radiologists evaluated the quality of scans for image contrast and streak artifacts at 80 kVp, 120 kVp, and 80 kVp with wide window width display presets (W-80).
Results:
The estimated ED was 33% lower at 80 than at 120 kVp. CNR of the portal vein was 36.8% higher at 80 than 120 kVp, and for the liver it was 17.7% higher at 80 than 120 kVp. The visual score of image contrast was significantly higher for W-80 than for 120 kVp; however, there was no significant difference in the visual score of streak artifacts.
Conclusion:
At portal phase abdominal CT, 80 kVp and a high tube current-time product setting significantly improved image quality and reduced the radiation dose compared with 120 kVp.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...