Related Experiment Video
Updated: Jun 1, 2026

In Vivo Fiber-Coupled Pre-Clinical Confocal Laser-scanning Endomicroscopy (pCLE) of Hippocampal Capillaries in Awake Mice
Published on: April 21, 2023
Frameless stereotactic endoscope-assisted transoccipital hippocampal depth electrode placement: cadaveric
Biji Bahuleyan1, Melvin Omodon, Shenandoah Robinson
1Division of Pediatric Neurosurgery Rainbow Babies and Children's Hospital The Neurological Institute, Case Western Reserve University School of Medicine, Rainbow B-501, Cleveland, OH, 44106, USA.
Purpose:
Hippocampal recording using depth electrodes is indicated in a small subgroup of patients with medically intractable seizures. There are several conventional techniques for implantation of hippocampal depth electrodes. We describe a new method for hippocampal depth electrode placement using an image-guided endoscopic transoccipital route. This technique is simple and effective, eliminating several drawbacks of conventional techniques.
Methods:
One silicone-injected cadaver head was used. A rigid endoscope sheath was inserted through a transoccipital corridor into the atrium of the lateral ventricle and then advanced to the temporal horn. Each of the hemispheres was cannulated. The hippocampus was identified visually, and a depth electrode was inserted into the substance of the hippocampus along its long axis under direct vision.
Results:
In both hemispheres we were able to successfully implant the depth electrode within the hippocampus. The advantages of our technique over conventional approaches are (1) there is no need for frame-based stereotaxy, thus reducing operating time and patient discomfort, (2) the electrodes are inserted into the hippocampus under direct endoscopic visualization, reducing the chance of injury to vascular structures, (3) there is no need to insert a larger cannula into the hippocampus before placement of the electrodes, reducing trauma to the hippocampus, and (4) the number of electrodes within the hippocampus can be assessed at the end of the procedure, reducing malposition.
Conclusion:
We believe that image-guided endoscopic transoccipital hippocampal depth electrode placement can be performed with precision equal or superior to conventional techniques but without their major disadvantages.
More Related Videos
04:50Operative Technique and Nuances for the Stereoelectroencephalographic (SEEG) Methodology Utilizing a Robotic Stereotactic Guidance System
Published on: June 9, 2023
06:58Non-restraining EEG Radiotelemetry: Epidural and Deep Intracerebral Stereotaxic EEG Electrode Placement
Published on: June 25, 2016