Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
On-chip solid phase extraction and enzyme digestion using cationic PolyE-323 coatings and porous polymer monoliths
Yujuan Hua1, Abebaw B Jemere, D Jed Harrison
1Department of Chemistry, University of Alberta, Edmonton, AB, Canada.
Abstract:
We evaluate the compatibility and performance of polymer monolith solid phase extraction beds that incorporate cationic charge, with a polycationic surface coating, PolyE-323, fabricated within microfluidic glass chips. The PolyE-323 is used to reduce protein and peptide adsorption on capillary walls during electrophoresis, and to create anodal flow for electrokinetically driven nano-electrospray ionization mass spectrometry. A hydrophobic butyl methacrylate-based monolithic porous polymer was copolymerized with an ionizable monomer, [2-(methacryloyloxy)ethyl] trimethylammonium chloride to form a polymer monolith for solid phase extraction that also sustains anodal electroosmotic flow. Exposure of the PolyE-323 coating to the monolith forming mixture affected the performance of the chip by a minor amount; electrokinetic migration times increased by ∼5%, and plate numbers were reduced by an average of 5% for proteins and peptides. 1-mm long on-chip monolithic solid phase extraction columns showed reproducible, linear calibration curves (R(2)=0.9978) between 0.1 and 5 nM BODIPY at fixed preconcentration times, with a capacity of 2.4 pmol or 0.92 mmol/L of monolithic column for cytochrome c. Solution phase on-bed trypsin digestion was conducted by capturing model protein samples onto the monolithic polymer bed. Complete digestion of the proteins was recorded for a 30 min stop flow digestion, with high sequence coverage (88% for cytochrome c and 56% for BSA) and minimal trypsin autodigestion product. The polycationic coating and the polymer monolith materials proved to be compatible with each other, providing a high quality solid phase extraction bed and a robust coating to reduce protein adsorption and generate anodal flow, which is advantageous for electrospray.
More Related Videos
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...