Polarization-Sensitive Two-Photon Microscopy for a Label-Free Amyloid Structural Characterization
Published on: September 8, 2023
An imaging technique using rotational polarization microscopy for the microstructure analysis of carbon/carbon
Li Miaoling1, Qi Lehua, Li Hejun
1School of Mechatronics, Northwestern Polytechnical University, Xi'an, China.
Abstract:
A novel image analysis technique was proposed for microstructure investigation of carbon/carbon (C/C) composites. The rotational polarization microscopy was developed to meet the special imaging requirements. The samples of C/C composites were observed in reflection polarized light microscope, where the analyzer was rotated instead of the stage, and the polarizer was taken out. The bireflectance of like-graphite negative uniaxial crystal was analyzed. It was the theoretic foundation of image collection and data processing. The analyzer was rotated through 36 × 10° intervals without any movement of the specimen. The polished cross-section of C/C composites took micrographs at each analyzer orientation. All image data collected from the same field of view were processed by image registration and image fusion. The synthesized images were obtained by calculating the maximum and minimum gray values and their differences at each point of the million pixels at 18 orientations of the analyzer. They are unique and quite reliable to be applied to analyze the microstructure of C/C composites. Subsequently, image segmentation was performed, and the feature parameters of each component were calculated. Good agreement was found between the results from image analysis and experimental data.
Related Concept Videos
Three-Dimensional Microscopy in Microbiology
Two-Dimensional Microscopy in Microbiology
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Confocal Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Overview of Microscopy Techniques