Application of rhodamine 800 for reversed phase liquid chromatographic detection using visible diode laser-induced
1Department of Pharmacy and Pharmaceutics, Medical College of Virginia, Richmond, Virginia 23298-0533.
Abstract:
This study reports the application of rhodamine 800, a far-red dye, suitable for excitation using visible diode laser-induced fluorescence (VDLIF) detection. A reagent synthesized from rhodamine 800 was evaluated as a precolumn reagent for derivatization with amino-containing analytes. The derivative of this reagent with primary amine analytes showed a loss of fluorescence. Rhodamine 800 was then applied as a mobile phase additive in the indirect mode for quantitation of valproic acid in plasma using reversed phase HPLC in combination with VDLIF detection. A visible diode laser (output power 8.50 mW) temperature-tuned to oscillate at 674.70 nm was used as a light source for a laboratory constructed HPLC fluorescence detector. A liquid/liquid extraction procedure was applied to human blank plasma. The selectivity of this method was validated by demonstration of a lack of interfering peaks in extracts of plasma (n = 3 sources). A calibration curve for valproic acid between 40 and 200 μg/mL was shown to be linear (r = 0.9932). The recoveries of valproic acid at concentrations of 50 and 100 μg/mL were evaluated and determined to be 73 and 72%, respectively. The precision and accuracy (n = 5) of the assay was within 7.0% RSD and 8.0% difference from the spiked concentration, respectively. The limits of detection (S/N = 3) for extracted and unextracted valproic acid were 15.0 and 11.54 μg/mL, respectively. The theoretical (C(lim)) and practical (C(det)) limits of detection in the detector flow cell for unextracted valproic acid at a S/N = 1 were found to be within 15%.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Photoluminescence: Applications