A Comparison of Cryofocusing Injectors for Gas Sampling and Analysis in Fast GC
A J Borgerding1, C W Wilkerson
1Chemical Science and Technology Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545.
Abstract:
The performance of two cryofocusing injectors for fast gas chromatography has been studied. The first system traps analytes onto bare metal tubes and rapidly vaporizes them upon ballistically heating the tube using a capacitance discharge. The second is a microloop injector in which analytes are cryotrapped onto short lengths of narrow-bore fused silica tubing with various coatings. The ballistically heated injector is capable of sampling and injecting compounds from air faster than the microloop system, because the metal tube can be heated and cooled more rapidly. Both systems are capable of cryotrapping compounds as volatile as butane at -90 °C, and the microloop system can trap ethane when a section of a porous layer open-tubular (PLOT) column is used as the sample loop. In addition, the microloop injector can be used without cryointegration to analyze compounds regardless of their volatility, as long as they are present in the samples at detectable concentrations. Because the ballistically heated injector is flushed prior to injection, it can introduce only compounds that are adsorbed onto its metal trap. Comparison of chromatograms obtained using the two injectors show similar chromatographic resolution. Both traps are susceptible to freezing during the cryotrapping step, but the use of an inline Nafion dryer allows air saturated with water vapor to be sampled using both systems for 3 min without plugging the trap. Thermal decomposition during the injection step can occur for labile species in the ballistically heated trap, but even the highly unstable compound ethyl diazoacetate may be injected without breakdown in the microloop system.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Instrumentation