Rapid aqueous sample extraction of VOCs: effect of physical parameters
R W Current1, M J Meyer, A J Borgerding
1Department of Chemistry, University of North Dakota, P.O. Box 9024, Grand Forks, ND 58202-9024, USA.
Abstract:
Rapid aqueous sample extraction (RASE) devices were constructed and characterized using m-xylene as a test analyte. Extraction of m-xylene from aqueous samples was studied under many different conditions, independently varying extractor volume, extraction gas flow rate, temperature, pressure, sample volume, and sample concentration. Gas samples were analyzed as controls to determine the non-extraction (transport) component of the analyte pulse width. The extraction of analyte from water to the gas phase took proportionately longer (compared to transport) for RASE apparatus that had a volume greater than 10 ml. An order of magnitude change in RASE volume resulted in larger than an order of magnitude change in extraction time and total analyte pulse width. The flow rate of the extraction gas had a much larger effect on a RASE apparatus with a volume greater than 10 ml. For these large extractors, both extraction time and total analyte pulse width decreased by a factor of 4 for a flow increase from 40 to 120 ml min(-1). There was little change at higher flow rates, or for extractors with smaller volumes. Temperatures below 40 degrees C resulted in large increases in the pulse duration due to broadening during transport. The temperature effect on extraction time was only a factor of 2 over a range from 25 to 85 degrees C. Pressure also had only a relatively small effect, increasing extraction time and total pulse width by a factor of 2 over a range from 12 to 34 PSI. There was no observed change in either extraction time or total pulse width when the sample volume injected varied from 10 to 1000 mul, or over a concentration range from 170 to 17 000 mug l(-1). RASE apparatus were capable of complete extraction of analyte from water in less than 5 s under optimized conditions.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
08:57VacuSIP, an Improved InEx Method for In Situ Measurement of Particulate and Dissolved Compounds Processed by Active Suspension Feeders
Published on: August 3, 2016
Related Concept Videos
Volatilization
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Extraction: Effects of pH
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...