Related Experiment Video
Updated: Jun 1, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Dose calculation for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema
T T Monajemi1, Charles M Clements, Ron S Sloboda
1Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada.
A new method models prostate implant edema, revealing underdosage that varies with seed position and edema severity. This approach improves dosimetry calculations for permanent prostate brachytherapy.
Area of Science:
- Medical Physics
- Radiotherapy Dosimetry
Background:
- Permanent prostate implants are used for brachytherapy.
- Prostatic edema (swelling) can affect radiation dose distribution.
- Accurate dosimetry is crucial for effective treatment and minimizing side effects.
Purpose of the Study:
- To develop a dose calculation method for permanent prostate implants that accounts for clinically relevant edema.
- To quantify the preimplant dosimetry error caused by edema using this new method.
Main Methods:
- Developed a model for spatially anisotropic, time-resolving prostatic edema based on MRI data.
- Extended the TG-43 dose calculation formalism to incorporate the edema model.
- Calculated preimplant dosimetry error for 125I, 103Pd, and 131Cs seeds under various edema conditions.
Main Results:
- The developed method indicated underdosage in the calculation volume, dependent on seed and calculation point positions.
- Dosimetry errors increased with greater edema magnitude and duration.
- For average edema, mean errors were 8.3% for 131Cs, 7.5% for 103Pd, and 2.2% for 125I seeds.
Conclusions:
- A novel dose calculation method for permanent prostate implants incorporating anisotropic, time-resolving edema was established.
- This method provides different dosimetry error values compared to isotropic edema models.
- The method is applicable for calculating dosimetry corrections when edema can be estimated or measured.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
11:11Longitudinal Measurement of Extracellular Matrix Rigidity in 3D Tumor Models Using Particle-tracking Microrheology
Published on: June 10, 2014