Spectroelectrochemical sensing based on multimode selectivity simultaneously achievable in a single device. 2.
Y Shi1, C J Seliskar, W R Heineman
1Department of Chemistry, University of Cincinnati, P.O. Box 210172, Cincinnati, Ohio 45221-0172.
Abstract:
Three modes of selectivity based on charge-selective partitioning, electrolysis potential, and spectral absorption wavelength were demonstrated simultaneously in a new type of spectroelectrochemical sensor. Operation and performance of the three modes of selectivity for detection of analytes in the presence of direct interferences were investigated using binary mixture systems. These binary mixtures consisted of Fe(CN)(6)(3-) and Ru(bpy)(3)(2+) and of Fe(CN)(6)(4-) and Ru(CN)(6)(4)(-) in aqueous solutions. Results on the Fe(CN)(6)(3-)/Ru(bpy)(3)(2+) binary mixture showed that an anion-exchange coating consisting of PDMDAAC-SiO(2) [where PDMDAAC is poly(dimethyldiallylammonium chloride)] and a cation-exchange coating consisting of Nafion-SiO(2) can trap and preconcentrate analytes with charge selection. At the same time, such coatings exclude interferences carrying the same type of charge as that of the exchange sites in the sensor coating. Using the Fe(CN)(6)(4-)/Ru(CN)(6)(4-) binary mixture, the Fe(CN)(6)(4-) component can be selectively detected by restricting the modulation potential cycled to a range specific to the redox-active Fe(CN)(6)(4-) component and simultaneously monitoring the optical response at the overlapping wavelength of 420 nm. It was also shown that, when the wavelength for optical monitoring was chosen as 500 nm, which is specific to the Ru(CN)(6)(4-) component, interference from the Fe(CN)(6)(4-) component for spectroelectrochemical detection of Ru(CN)(6)(4-) was significantly suppressed, even though the cyclic modulation potential encompassed the redox range for the Fe(CN)(6)(4-) component.
More Related Videos
08:49Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy
Published on: December 1, 2023
10:59Tracking Electrochemistry on Single Nanoparticles with Surface-Enhanced Raman Scattering Spectroscopy and Microscopy
Published on: May 12, 2023
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Tandem Mass Spectrometry
UV–Vis Spectrometers
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...