Longitudinally modulated cryogenic system. A generally applicable approach to solute trapping and mobilization in gas
1Department of Applied Chemistry, Royal Melbourne Institute of Technology, GPO Box 2476V, Melbourne, Victoria 3001, Australia.
Abstract:
This paper describes a novel approach to solute trapping and remobilization. It involves the use of a subambient trap, with a narrow capillary column passing through the cooled region. A mechanism allows for longitudinal movement of the trap relative to the chromatographic column or narrow transfer line through which analytes travel. Either the trap or the column can be moved, and the frequency or manner of relative movement determines the type of result obtained. A series of preliminary studies are described that define the general approach to using this device and demonstrate the unique benefits that may arise from the modulation movement. Significant improvement (reduction) in peak width occurs if the device is placed immediately prior to the detection system, and consequently a great increase in detection limits results. With a 25 cm length of capillary column between the trap and detector, it is calculated that the plate height of dodecane is 0.082 mm, equivalent to 12 100 plates/m. This was found to be much greater than that for dodecane analyzed on a 25 m column. By slow displacement of the column through the trap, it is demonstrated that the solute is trapped in the first 1 cm (or less) of the column located in the cold trap.
More Related Videos
06:42Cryogenic Sample Loading into a Magic Angle Spinning Nuclear Magnetic Resonance Spectrometer that Preserves Cellular Viability
Published on: September 1, 2020
10:54Dissolution Dynamic Nuclear Polarization Instrumentation for Real-time Enzymatic Reaction Rate Measurements by NMR
Published on: February 23, 2016
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Elution Process