Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
Emission Spectra02:39

Emission Spectra

When solids, liquids, or condensed gases are heated sufficiently, they radiate some of the excess energy as light. Photons produced in this manner have a range of energies, and thereby produce a continuous spectrum in which an unbroken series of wavelengths is present.
Spectrophotometry: Introduction01:16

Spectrophotometry: Introduction

Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Design of a hyperspectral imaging gonioradiometer for appearance characterization.

Optics express·2025
Same author

Assessment of color preference, purchase intention and sexual attractiveness of lipstick colors under multiple lighting conditions.

Frontiers in neuroscience·2023
Same author

Domain and range of the CIECAM16 forward transformation.

Optics express·2023
Same author

Road marking BRDF model applicable for a wide range of incident illumination conditions.

Journal of the Optical Society of America. A, Optics, image science, and vision·2023
Same author

Extending the color discrimination metric with consideration of illuminance level.

Optics letters·2022
Same author

Spectral Reconstruction Using an Iteratively Reweighted Regulated Model from Two Illumination Camera Responses.

Sensors (Basel, Switzerland)·2021

Related Experiment Video

Updated: Jun 1, 2026

Measuring Spatially- and Directionally-varying Light Scattering from Biological Material
11:57

Measuring Spatially- and Directionally-varying Light Scattering from Biological Material

Published on: May 20, 2013

Luminance-based specular gloss characterization.

Frédéric B Leloup1, Michael R Pointer, Philip Dutré

  • 1Light & Lighting Laboratory, Catholic University College Sint-Lieven, B-9000, Gent, Belgium. Frederic.Leloup@kahosl.be

Journal of the Optical Society of America. A, Optics, Image Science, and Vision
|June 7, 2011
PubMed
Summary

This study reveals illumination conditions significantly impact gloss perception, challenging current glossmeters. A new metric combining surface and lighting properties offers improved gloss evaluation for high-gloss materials.

More Related Videos

Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
06:55

Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses

Published on: June 6, 2017

Related Experiment Videos

Last Updated: Jun 1, 2026

Measuring Spatially- and Directionally-varying Light Scattering from Biological Material
11:57

Measuring Spatially- and Directionally-varying Light Scattering from Biological Material

Published on: May 20, 2013

Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
06:55

Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses

Published on: June 6, 2017

Area of Science:

  • Optics
  • Visual Perception
  • Materials Science

Background:

  • Gloss perception is influenced by surface properties and illumination.
  • Existing glossmeters struggle with accurate high-gloss surface evaluation due to illumination variability.
  • Understanding illumination's role is crucial for precise gloss measurement.

Purpose of the Study:

  • To investigate the influence of illumination conditions on specular gloss perception.
  • To develop a psychophysical model correlating visual gloss estimations with luminance.
  • To create a novel metric for enhanced gloss evaluation.

Main Methods:

  • Magnitude estimation experiment with 10 observers.
  • Utilized a light booth with two independently controlled light sources.
  • Derived a psychophysical scaling function relating visual gloss to luminance measurements.

Main Results:

  • A model was developed relating visual gloss to the luminance of the reflected image and background.
  • Validation experiment confirmed the model's generalization error.
  • A new metric incorporating both surface and illumination properties was established.

Conclusions:

  • Illumination conditions are critical factors in gloss perception.
  • The developed metric provides a more accurate method for evaluating high-gloss surfaces.
  • This research can lead to improved gloss evaluation instruments and methods.